Patton electronic Patton Model 1092 Specifications, Temperature Range 32-122F 0 -50C

Models: 1092

1 19
Download 19 pages 57.39 Kb
Page 16
Image 16

2.If the above test indicates no errors are present, move the

V.52 toggle switch DOWN, activating the “511/E” test with errors present. If the test is working properly, the local modem's red “ER” LED will glow. A successful “511/E” test will confirm that the link is in place, and that the Model 1092’s built-in “511” generator and detector are working properly.

NOTE: The above V.52 BER tests can be used independently of the Remote Digital Loopback tests. This requires two operators: one to initiate and monitor the tests at the local Model 1092, and one to do the same at the remote Model 1092. In this case, the test pattern sent by each Model 1092 will not be looped back, but will be transmitted down the line to the other Model 1092. While one operator initiates test, the other monitors for errors.

APPENDIX A

PATTON MODEL 1092 SPECIFICATIONS

Transmission Format: Synchronous or asynchronous

Transmission Line: Single unconditioned twisted pair

Clocking: Internal, external or receive loopback

Distance: Distance, max, all data rates:

10.1miles (16.4km) on 19 AWG (0.9mm) wire

7.2miles (11.5 km) on 22 AWG (0.64mm) wire

5.0(8 km) on 24 AWG (0.5mm) wire

3.4(5.5 km) on 26 AWG (0.4mm) wire

Interface Modules: EIA RS-232/CCITT V.24, RS-232/530, CCITT V.35 and CCITT X.21

Data Rates: Synchronous 32, 56, 64 & 128 kbps; Asynchronous 0 - 38.4 kbps

Diagnostics: V.52 compliant bit error rate pattern (511/511E pattern) generator and detector with error injection mode; Local Line Loopback and Remote Digital Loopback, activated by front panel switch or via serial interface

LED Status Indicators: TD, RD, CTS, CD, DTR, NS(no signal), ER (error) and TM (test mode)

Connectors: RJ-45 on line side; DB-25 female, M/34 female or DB-15 female on serial interface side, depending upon which interface module is installed.

Power: 120/230 VAC (switch selectable), 50-60 Hz; 100-253 VAC, 50-60 Hz (universal input option); 48 VDC (option). 5 watts.

Temperature Range: 32-122°F (0° -50°C)

Altitude: 0-15,000 feet

Humidity: 5 to 95% noncondensing

Dimensions: 7.3” x 6.6” x 1.62” (185mm x 168mm x 41mm)

Weight: 2.01 lbs. (1.0kg)

29

30

Page 16
Image 16
Patton electronic user manual Patton Model 1092 Specifications, Temperature Range 32-122F 0 -50C