1. DTE Rate

Select Option 1 in the SOFTWARE CONFIGURATION menu to

select the async. or sync. DTE Rate of the Model 1092. Different DTE Rate menu screens will display for async. or sync. bit rates. The selections are shown below.

a) This menu is displayed when the data format is synchronous:

b) This menu is displayed when the data format is asynchronous:

2. Data Format

Select Option 2 in the SOFTWARE CONFIGURATION Menu to select the async or sync data format (See below).

3. Clock Mode

Select Option 3 in the SOFTWARE CONFIGURATION Menu to select the sync clock mode (See below).

Set this option as follows:

Master Clock - Internal: Selection 1 allows the Model 1092 to generate an internal clock as the timing source.

Master Clock - External: Selection 2 allows the Model 1092 to Derive the system clock from the locally connected DTE.

Slaved to Receive Clock: Selection 3 to allows the Model 1092 to derive the timing source from the incoming data stream from the remote Model 1092.

Important: One 1092A must be a Master Clock (either internal or external) and the other must be Slaved to the Receive Clock.

4. DSR During Local Line Loop

Select Option 4 in the SOFTWARE CONFIGURATION to configure the behavior of the local Data Set Ready (DSR) signal during the Local Line Loop test mode (below).

13

14

Page 8
Image 8
Patton electronic 1092 user manual DTE Rate, Data Format, Clock Mode, DSR During Local Line Loop