4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the VDSL line rate, symmetric or asymmetric, Ethernet full auto sense capability (100BaseT full or half duplex, 10BaseT full or half duplex) or limited auto sense (only 100BaseT half duplex, 10BaseT full or half duplex). Table 1 summarizes default positions of DIP switches S1-1 through S1-4. Detailed descrip- tions of each switch follow the table.

Table 1: S1 Summary

Position

Function

 

Factory Default

 

 

 

 

S1-1

Ethernet Auto Sense

OFF

Full Auto Sense capability

S1-2

Line Rate

ON

 

 

 

 

 

S1-3

Line Rate

OFF

12.5Mbps Symmetric

 

 

 

 

S1-4

Line Rate

OFF

 

 

 

 

 

Switch S1-1: Ethernet Auto Sense

Use switch S1-1 to configure the unit for full auto sense capability or lim- ited auto sense capability. Full Auto sense capability consists of stan- dard Ethernet Auto sensing (100BaseT full duplex, 100BaseT half duplex, 10BaseT full duplex, and 10BaseT half duplex). Limited Auto sensing capability consists on only auto sensing for 100BaseT half duplex, 10BaseT full duplex, and 10BaseT half duplex. The limited auto sensing feature is used when an Ethernet device does not comply with IEEE 802.3x (back pressure flow control) at 100M full duplex.

Table 2: Ethernet Auto Sense Selection Chart

S1-1

Setting

 

 

OFF

Full Auto Sensing

 

(100 Mbps, Full or Half Duplex)

 

(10 Mbps, Full or Half Duplex)

 

 

ON

Limited Auto Sensing

 

(100 Mbps Half Duplex)

 

10 Mbps Full or Half Duplex)

 

 

Switches S1-2 and S1-4: Data Rate

Use switches S1-2 and S1-4 to configure the VDSL line rates.

Table 3: Symmetric VDSL Line Rates Selection Chart

S1-2

S1-3

S1-4

Symmetric Line Rate

 

 

 

 

ON

ON

ON

6.25 Mbps

ON

ON

OFF

9.38 Mbps

 

 

 

 

17

Page 17