Patton electronic 3040/V35 manual On DB-25

Models: 3040/V35

1 23
Download 23 pages 44.24 Kb
Page 22
Image 22

APPENDIX

139010BPN

J1

 

 

V.35 on DB-25

 

J2

J3

 

J4

J5

J6

 

 

JP8 thru JP12 Installed forces DTR/DSR for the channel

 

SW5

SW6

SW7 SW8

SW9

SW10

SW11 SW12

SW13

SW14

139001UA

PATTON

No Data Timer - SW15

3 4 Count ON ON 16 ON OFF 64 OFF ON 256

OFF OFF 2048

DTE

DCE

SW15

JP8

JP9

JP10

JP11

JP12

SW16

SW17

 

SW18

 

ELECTRONICS CO.

A-6

CTS Delay Timer - SW16

1 2 3 Delay

ON ON ON No Delay

OFF ON ON 1 mS ON OFF ON 2 mS OFF OFF ON 4 mS ON ON OFF 8 mS OFF ON OFF 16 mS ON OFF OFF 32 mS OFF OFF OFF 64 mS

8 7 6 5 4 3 2 1

OF F ON

Signal to Chassis Ground Unused

No Data Timeout

Baud Rate Selection

8 7 6 5 4 3 2 1

OF F ON

CTS Delay

Sync=ON /Async=OFF

Priority=ON /Scan=OFF

FB on CLK=ON /FB on DCD=OFF FB Disable=ON /FB Enable=OFF Int Clk FB=ON /Ch4 FB=OFF

8 7 6 5 4 3 2 1

OF F ON

Tx Clock Source

TXC pinsY,AA=ON / pinsU,W=OFF Ch1 RTS=ON /Data=OFF

Ch2 RTS=ON /Data=OFF

Ch3 RTS=ON /Data=OFF

Ch4 RTS=ON /Data=OFF

8 7 6 5 4 3 2 1

OF F ON

Anti-Stream Timer

Rx Clock Source

Rcvr Gated=ON /Broadcast=OFF Anti-Stream Enabled=ON

3040/V35

Jumpers

JP3

 

 

JP2

HS Option

 

 

Test

 

JP7

256Kbps

 

JP6

512Kbps

 

JP1

 

JP5

1024Kbps

Baud Rate Select - SW15

5 6 7 8 Rate

ON ON ON ON HS Option OFF ON ON ON 768K ON OFF ON ON 384K OFF OFF ON ON 192K ON ON OFF ON 128K OFF ON. OFF ON. 72K

ON OFF OFF ON. 64K OFF OFF OFF ON 57.6K

ON ON ON OFF 56K

 

TX Clock Source - SW17

RX Clock Source - SW18

 

 

1

 

2

3

 

Source

 

 

4

5

6

 

Source

 

 

 

ON

ON

ON

Master

 

 

ON

ON

ON

Master

 

 

 

OFF

ON

ON

Chan1

 

OFF

ON

ON

Chan1

 

 

 

ON

OFF

ON

Chan2

 

ON

OFF

ON

Chan2

 

 

 

OFF OFF

ON

Chan3

 

OFF OFF

ON

Chan3

 

 

 

ON

ON

OFF

Chan4

 

ON

ON

OFF

Chan4

 

 

 

OFF

ON

OFF

Unused

 

OFF

ON

OFF

Unused

 

 

 

ON

OFF OFF

Unused

 

ON

OFF OFF

Unused

 

 

 

OFF OFF OFF

Internal

 

OFF OFF OFF

Internal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anti-Stream Timer - SW18

1 2 3 Count ON ON ON 1024 OFF ON ON 2048 ON OFF ON 4096 OFF OFF ON 16K ON ON OFF 64K OFF ON OFF 256K ON OFF OFF 1M

OFF OFF OFF 2M

Factory

JP4 2048Kbps

 

OFF ON. ON OFF 48K ON. OFF ON OFF 38.4K OFF OFF ON OFF 28.8K

Port Enable(Green) / Disable(Black)

Fall

Back

Power SD RD Clocking

ON. ON OFF OFF 19.2K OFF ON. OFF OFF 14.4K ON. OFF OFF OFF 9.6K OFF OFF OFF OFF 4.8K

Active

1 2 3 4

Anti-Stream

1 2 3 4

Port 1

Port 2

Port 3

Port 4

INSTALLATION AND OPERATIONS MANUAL

Page 22
Image 22
Patton electronic 3040/V35 manual On DB-25