Patton electronic 3088RC user manual Reset Configuration To Factory Default

Models: 3088RC RocketLink-G NTU Rack Mount G.SHDSL Modem Card

1 60
Download 60 pages 17.5 Kb
Page 52
Image 52

7.Open Model 3088RC Console (via HyperTerminal or other terminal emulation program).

>>Transfer

>>Send Text File...

>>Set “Files of Type:” to “All files (*.*)” >>Select 033252Z.hex

8.When the transfer completes, turn off the Model 3088RC.

9.Set the DIP switches for the proper conÞguration.

10.Turn on the Model 3088RC. It now operates with the upgraded soft- ware.

5.5 RESET CONFIGURATION TO FACTORY DEFAULT

The conÞguration can be reset to factory defaults from the software reset mode. This allows a user to recover from a forgotten password. To reset to the conÞguration, follow these steps:

1.Power down the unit.

2.Set all DIP switches to the OFF position.

3.Connect a PC to the Console port.

4.Open a VT100 terminal emulator (such as HyperTerminal). ConÞg- ure the emulator for 19200 bps,1 stop bit, no parity, X-ON X-OFF ßow control.

Note The 3088RC will not wait for its address to be selected when in software reset mode. It will automatically accept data from the 1001CC.

5.Power up the unit. The terminal should display the following mes- sage: Reset Mode.

6.Type the ‘*’ key. You will see a ‘:’ prompt.

7.Type the command reset.

8.When the command completes, the unit has been reset to factory conÞguration.

9.Set the DIP switches to the desired conÞguration. Power cycle the unit to begin using the new conÞguration.

52

Page 52
Image 52
Patton electronic 3088RC, RocketLink-G NTU Rack Mount G.SHDSL Modem Card user manual Reset Configuration To Factory Default