Patton electronic 3088RC user manual A.7 CONFIGURATION, A.8 TRANSMISSION LINE, A.9 LINE CODING

Models: 3088RC RocketLink-G NTU Rack Mount G.SHDSL Modem Card

1 60
Download 60 pages 17.5 Kb
Page 54
Image 54

test mode is in progress. It blinks once if an error is detected either during a test mode, or in normal DSL operation.

A.7 CONFIGURATION

ConÞguration is done with either externally accessible DIP switches, CLI or through the EOC (Embedded Operations Channel) from a Model 3096RC G.SHDSL concentration card.

A.8 TRANSMISSION LINE

Single Twisted Pair

A.9 LINE CODING

TC-PAM (Trellis Coded Pulse Amplitude Modulation)

A.10 LINE RATES (DSL LINE)

All nx64 rates from 64 kbps up to 4.6 Mbps

A.11 LINE INTERFACE

Transformer coupled, 2500 VRMS isolation

A.12 G.SHDSL PHYSICAL CONNECTION

RJ-45, 2-wire polarity insensitive pins 4 and 5

A.13 ENVIRONMENT

Operating temp: 32–122°F (0–50°C)

Humidity: 5–95% non-condensing

Altitude: 0–15,000 feet (0–4,600 meters)

54