Paxar Monarch Pathfinder Ultra Gold manual C h i n e Fault s

Models: Monarch Pathfinder Ultra Gold

1 216
Download 216 pages 44.02 Kb
Page 170
Image 170

580Out of memory. Try to reallocate memory. Resend the packet. If the error persists, call Technical Support.

603Internal software error caused by the batch not being held. Turn off the printer. Wait two seconds and turn it back on. If the error persists, call Technical Support.

611Font, bar code or density is invalid. The font, bar code or density in the batch does not fit the format.

612The data in this line of the batch is either missing or does not match the format.

613Reference point off tag.

614Portion of field off tag. There may be an invalid character in the packet. Make sure you did not enter O for .

615Bar code width is greater than 16 inches or the number of keywords for your PDF 417 bar code exceeds 928. Decrease the density or shorten the amount of data to print the bar code.

616Dot shifting failed. A bad dot falls on a bar code that cannot be shifted. Call Technical Support.

618Magnification must be 1 to 7.

M a c h i n e F a u l t s

Errors 700 to 799 occur when there is a problem with the printer.

703The printer sensed a calibration of different-sized black marks. Make sure the correct supply is loaded.

704Printer has not sensed a supply mark within the specified number of inches or out of supplies. Check the supply tracking, supply marks, black mark sensor position, and supply roll for binding. If the error continues to appear, change the supply.

706The printer’s motor stalled.

730A memory allocation error occurred during initialization.

750Printhead is overheated. Turn off the printer to let the printhead

12-10Troubleshooting

Page 170
Image 170
Paxar Monarch Pathfinder Ultra Gold manual C h i n e Fault s