3. OPERATING INSTRUCTIONS

3. OPERATING INSTRUCTIONS

(1)Power on: when powering up the microphone, switch the power switch (2) to the ON position- The Battery Status indicator will flash briefly, indicating normal operational status. (b)When the indicator remains illuminated or does not illuminate at all, the battery level is low or exhausted and must be replaced for continued operation.

(2)Determine Channel/Group: After you power up the transmitter, check to see that it is assigned to the same channel/group as the receiver. If you find they do not match then follow the G/CH setup procedures (pages 8 -9).

4. FUNCTIONS OF LCD DISPLAY

(1)"ERR" Message: when "ERR" appears in the display it indicates that an operational error has occurred. Please refer to the following codes to diagnose which error you are experiencing.

ERR no01 - EEPROM is not being programmed or internal data error ERR no02 - For testing only

ERR no03 - The frequency you are about to program into the system exceeds the microphone's frequency upper limit (At this time the microphone is still operable and the frequency remains unchanged. To clear the "ERR" message

in the LCD display, simply turn off the power and switch back on.).

ERR no04 - The frequency you are about to program into the system is below the microphone’s frequency lower limit (At this time the microphone is still operable and the frequency remains unchanged. To clear the “ERR” message in LCD display, simply turn off the power and switch back on.).

27