DIP SWITCHES

With the front panel removed, DIP switch 1 and DIP switch 2 are visible. These two ten-position DIP switches configure and define many functions of the CM9760-VCRC-P.

Figure 3 identifies the relative locations of DIP switches 1 and 2.

DIP switch functions are discussed in the Setup section.

LEDs

The green POWER LED located on the left front panel of the unit comes ON at power up.

The red DATA LED located on the right side of the front panel continually flashes on and off at a regular rate (about 1/2 second intervals) until the first valid command is received. The LED will not flash again until another valid command is received. Also, in cascaded situa- tions, if a command is meant for a VCRC-P further down the chain, the command will be re- layed down the chain and the LED will not come on until the appropriate VCRC-P processes the command. In other words, LED activity is address specific. Additionally, if power is cycled, or if the DIP switch slide positions are moved, or if a front panel reset occurs, then the LED will again flash intermittently until the first valid command is received.

Figure 3. DIP Switch Location

Pelco Manual C1943M (9/99)

5

Page 5
Image 5
Pelco c1943m operation manual DIP Switches, LEDs