Specifications

MODEL NUMBER

GW5000 Interface between Endura system and a public network with limited bandwidth

VIDEO/AUDIO

Video Standards NTSC/PAL/EIA/CCIR composite
Video Compression MPEG-4
Video Streams 2, simultaneous per input
Video Resolutions NTSC PAL
4CIF 704 x 480 704 x 576
2CIF 704 x 240 704 x 288
CIF 352 x 240 352 x 288

NETWORK

Interface (private) 1 Gigabit Ethernet RJ-45 ports (1000Base-T)
Interface (public) 56 kbps to 100 Mbps (100Base-T)

FRONT PANEL INDICATORS/FUNCTIONS

Power Blue
CPU Activity Yellow
Network Activity Green
Network Status Gr een, amber, red
Unit Status Green, amber, red
Power Button On, off (soft), off (hard)

POWER

Power Input 100-240 VAC, 50/60 Hz, 0.7 A, autoranging
Cable Type 1 USA (117 VAC), 1 European (220 VAC), 1 UK (250 VAC)
All, 3 prongs, molded connector, 6 ft (1.8 m) cord
Power Consumption (maximum) 40 W, 137 BTU/H

ENVIRONMENTAL

Operating Temperature 50° to 95°F (10° to 35°C) at unit air intake (front of unit)
Storage Temperature -40° to 149°F (-40° to 65°C)
Operating Humidity 20% to 80%, noncondensing
Maximum Humidity Gradient 10% per hour
Operating Altitude -50 ft to 10,000 ft (-16 m to 3,048 m)
Operating Vibration 0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute
NOTE: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration,
floor layout, air conditioning strategy, and other issues. To prevent failure and unit damage, make sure the temperature at the unit is continuously