Installation and commissioning

8.05 Basic position of the machine drive unit

8.05.01 On machines with EcoDrive and control unit P40 ED

Switch on the machine.

Press the TE/speed key twice to select the input mode.

Select parameter "798" by pressing the corresponding +/- key, and select service level C, see Chapter Selecting the user level in the instruction manual for the control panel.

By pressing the corresponding +/- key select the parameter "799" (Selecting the machine class).

Check whether value "1" is set, and correct it if necessary.

If the parameter has to be altered, operate the TE/Speed key and then switch off the machine and switch it on again. Then select service level C again as described above.

By pressing the corresponding +/- key, select parameter "800" (selecting the sewing direction).

By pressing the corresponding +/- key, select the value for the parameter at "0".

By pressing the corresponding +/- key, select parameter "700".

Sew a stitch by operating the pedal.

Turn the balance wheel in the sewing direction until the descending needle is level with the top edge of the needle plate.

Then check the parameter values listed in the parameter list (see Chapter 10.04 Parameter Settings) and adjust them if necessary.

Conclude the adjustment of the sewing motor by pressing the TE/Speed key.

8.05.02 On machines with PicoDrive and control unit P40 PD2

Switch on the machine.

Call up the parameter input by pressing the "scroll" key.

To switch the function keys to input (LED in the TE key lights up), press the TE key.

By pressing the corresponding +/- keys, select parameter "798" and service level C, see Chapter Selecting the User Level in the separate Control Panel Instruction Manual.

Select parameter "799" by pressing the corresponding +/- keys.

Check whether the value is set at "2" and alter if necessary.

Switch the machine off and then on again.

Select parameter "800" by pressing the corresponding +/- keys.

Check whether the value is set at "0" (balance wheel turns towards the operator) and alter if necessary.

Select parameter "802" by pressing the corresponding +/- keys.

Check whether the value is set at "0" (= no reduction ratio) and alter if necessary.

24