Installation and commissioning
8.06 | Start inhibitor |
8.06.01 | Mounting the start inhibitor |
2
1
Fig. 8 - 07
●Set the machine into the table top.
●After loosening screws 2, set switch 1 so that it is activated when the sewing head is in an upright position.
●In this position tighten screws 2.
8.06.02 Checking the start inhibitor function
●Switch the machine on at the main switch and tilt back the sewing head.
●The error message "Er 0 16" (on
●If the message does not appear, check the setting of safety switch 2.
●After the sewing head has been returned to the upright position, the machine is ready for operation again.
26