Installation and commissioning

8.06

Start inhibitor

8.06.01

Mounting the start inhibitor

2

1

Fig. 8 - 07

Set the machine into the table top.

After loosening screws 2, set switch 1 so that it is activated when the sewing head is in an upright position.

In this position tighten screws 2.

8.06.02 Checking the start inhibitor function

Switch the machine on at the main switch and tilt back the sewing head.

The error message "Er 0 16" (on MD-4-95-220-CE) or "Error 9 (on Eco- or PicoDrive) must appear on the control panel.

If the message does not appear, check the setting of safety switch 2.

After the sewing head has been returned to the upright position, the machine is ready for operation again.

26