Care and maintenance

10.05 Parameter settings

Parameter settings are described in the separate operations manual for the drive, and may only be changed by qualifi ed technicians!

10.05.01

Parameter list for control unit P40 ED and P40 PD2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Group

Parameter

Description

User lever

 

Setting range

Set value P40 ED

Set value P40 PD2

 

 

 

 

 

 

 

 

 

 

 

1

105

Speed for start backtackl

B, C

300 - 2000

1200

1200

 

 

 

 

 

 

 

 

 

 

 

 

110

Speed for end backtack

B, C

300 - 2000

1200

1200

 

 

 

 

 

 

 

 

 

 

 

6

606

Speed min

B, C

30 - 300

180

180

 

 

 

 

 

 

 

 

 

 

 

 

607

Speed max.

B, C

300 - 6000

 

 

 

 

 

 

 

 

 

 

 

6

609

Cutting speed 1

B, C

60 - 300

180

180

 

 

 

 

 

 

 

 

 

 

 

 

 

660

Bobbin thread control

A, B,

0

- 2

0

-

 

 

 

 

0 = off, 1 = thread monitor,

C

 

 

 

 

 

 

 

 

2 = reverse counter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

668

Thread wiper/thread blower

B, C

0

- 1

0

-

 

 

 

 

1 = on; 0 = off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

700

Needle position 0

B, C

0 -255

*

*

 

 

 

 

(needle reference position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

702

Needle position 1 (needle lowered)

B, C

0 -

255

90

90

 

 

 

 

 

 

 

 

 

 

 

 

 

703

Needle position 2 (take-up lever raised)

B, C

0 -

255

236

236

 

 

 

 

 

 

 

 

 

 

 

 

 

705

Needle position 5 (end cutting signal 1)

B, C

0 -

255

200

200

 

 

 

 

 

 

 

 

 

 

 

 

 

706

Needle position 5 (start cutting signal 2)

B, C

0 -

255

136

136

 

 

 

 

 

 

 

 

 

 

 

 

 

707

Needle position 9 (start thread tension

B, C

0 -

255

164

164

 

 

 

 

release/start thread catcher)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

760

Multiplier for the fixed value (200)

A,B,

0 -

250

5

-

 

 

 

 

stitch count

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

797

Hardwaretest (OFF / ON ),

B, C

 

 

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

799

Selected machine class

C

1

- 3

1

2

 

 

 

 

 

 

 

 

 

 

 

 

8

800

Rotating direction of the motor

C

0

- 1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

802

Main drive reduction ratio

C

0

- 1

-

0

 

 

 

 

0 = 1:1, 1 = variable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See Chapter 3 Specifications

*Adjustment see Chapter 8.05 Basic position of the machine drive unit.

33