Care and maintenance

Group

Parameter

Description

User lever

Setting range

Set value P40 ED

Set value P40 PD2

 

 

 

 

 

 

 

9

985

Switch on angle for thread trapper

B, C

0 -255

67

67

 

 

 

 

 

 

 

 

986

Switch off angle for thread trapper

B, C

0 -255

206

206

 

 

 

 

 

 

 

 

989

Thread trapper at beginning of seam

B, C

0 - 2

0

0

 

 

1 = yes, 0 = no

 

 

 

 

 

 

 

 

 

 

 

10.05.02

Parameter list for control unit MD-4-95-220-CE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Description

Setting range

Set value

 

 

 

 

 

 

 

 

 

 

1

 

 

Speed max.

50 - 9999

 

 

 

 

 

 

 

 

 

 

4

 

 

Speed for start backtackl

50 - 8000

1500

 

 

 

 

 

 

 

 

 

 

5

 

 

Speed for end backtack

50 - 8000

1500

 

 

 

 

 

 

 

 

 

40

 

Thread wiper

ON - OFF

ON

 

 

 

 

 

 

 

 

 

46

 

Rotating direction of the motor

CW - CCW

CW

 

 

 

 

 

 

 

 

 

47

 

Selected machine class

0 - 101

62

 

 

 

 

 

 

 

 

 

61

 

Cutting speed 1

50 - 500

220

 

 

 

 

 

 

 

 

 

81

 

Needle position 6 (start cutting signal 2)

0 - 360°

40°

 

 

 

 

 

 

 

 

 

84

 

Needle position 5 (end cutting signal 1)

0 - 360°

90°

 

 

 

 

 

 

 

 

 

85

 

Needle position 9 (start thread tension

0 - 360°

120°

 

 

 

 

 

 

 

 

release/start thread catcher)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

87

 

Tension release after thread lever position at t.d.c.

0 - 1500ms

20ms

 

 

 

 

 

 

 

 

 

179

 

Needle position 2 (take-up lever raised)

0 - 359°

83°

 

 

 

 

 

 

 

 

 

181

 

Needle position 1 - needle lowered (192 = off)

0 - 255

250

 

 

 

 

 

 

 

 

 

210

 

Switch on angle for thread trapper

0 - 359°

20°

 

 

 

 

 

 

 

 

 

211

 

Switch off angle for thread trapper

0 - 359°

90°

 

 

 

 

 

 

 

 

 

236

 

Machine version

0 - 20

0

 

 

 

 

 

 

 

 

0 = 1183; 1 = 1181

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Further parameters see manual of the respective drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34