2.2 Programming

2.2.4VoIP Gateway/IP-PBX Interface Parameters

1. Click 1.4 VoIP Gateway/IP-PBX Interface Settings in the main menu.

2.Assign each parameter referring to the descriptions below. At any time during the session, you can:

Click ALL CLEAR to return all parameters to their previous values.

Click MENU to return to the main menu (see "2.1 Main Menu for the Administrator").

Click LOGOUT to log out from the IP-GW16 Maintenance Utility (see "2.5.2 Log Out").

3.Click OK.

You will see a confirmation screen.

Note

If your entry contains an invalid value, you will be prompted to correct your input. Enter correct values for the parameters shown in red and try again.

4.Confirm your entry and click OK.

To return to the previous screen, click CANCEL.

Parameter Descriptions

The parameters indicated with "*" must be changed while the VoIP Gateway Card is in the "STOP" status (see "2.3.1 Status Control"). The changes do not have to be followed by a reboot to become effective.

Dialing Settings

Parameter & Description

Default

Value Range

*

First Digit Time (s) 5-30s

20

5 to 30

 

Specifies the length of time (in seconds) within which the first

 

 

 

digit of a dial number must be dialed after seizing a VoIP

 

 

 

gateway trunk (CO line).

 

 

 

Generally, there is no need to change the default value.

 

 

 

 

 

 

*

Inter-Digit Time (s) 1-10s

5

1 to 10

 

Specifies the length of time (in seconds) within which

 

 

 

subsequent digits of a dial number must be dialed.

 

 

 

Generally, there is no need to change the default value.

 

 

26 Programming Guide