3.3 Data Management

Parameter & Description

Default

Value Range

 

 

 

Firmware Status

Display only

 

Indicates the current firmware status of the corresponding

 

 

page. There are 3 kinds of status indications:

 

 

• Main Operation Mode: Active firmware data on startup

 

 

under normal operation.

 

 

• OLD: Firmware data uploaded to the card before the

 

 

firmware data in the "Main Operation Mode" status was

 

 

uploaded.

 

 

• NEW: Firmware data uploaded to the card after the

 

 

firmware data in the "Main Operation Mode" status was

 

 

uploaded.

 

 

Note

 

 

The status indications "OLD" and "NEW" are irrelevant to

 

 

the version of the firmware data.

 

 

 

 

 

Startup Page

Display only

 

Indicates (with an "x" sign) the active page on startup.

 

 

Generally, the startup page is the firmware data whose status

 

 

is "Main Operation Mode".

 

 

The exception is when the card undergoes a reboot after a

 

 

firmware data upload operation; in this case, the card starts

 

 

up with the page in the "NEW" status. This is for the purposes

 

 

of confirming the result of the upload operation. If you reboot

 

 

again, the card starts up with the page in the "Main Operation

 

 

Mode" status.

 

 

To set the updated page as the active page on startup, you

 

 

must change its firmware status to "Main Operation Mode".

 

 

 

 

 

Operation

Not applicable

Empty,

Specifies whether to set the page (selected with the

 

Main Operation Mode

 

 

parameter Select Page) as the active page on startup ("Main

 

 

Operation Mode"), or delete the page ("Empty").

 

 

"Empty" is an option provided for engineer use only.

 

 

 

 

 

Select Page

Not applicable

Page-0,

Specifies the target page of the operation selected with the

 

Page-1

 

 

parameter Operation.

 

 

 

 

 

66 Programming Guide