3.3 Data Management
Parameter & Description | Default | Value Range |
|
|
|
Firmware Status | Display only |
|
Indicates the current firmware status of the corresponding |
|
|
page. There are 3 kinds of status indications: |
|
|
• Main Operation Mode: Active firmware data on startup |
|
|
under normal operation. |
|
|
• OLD: Firmware data uploaded to the card before the |
|
|
firmware data in the "Main Operation Mode" status was |
|
|
uploaded. |
|
|
• NEW: Firmware data uploaded to the card after the |
|
|
firmware data in the "Main Operation Mode" status was |
|
|
uploaded. |
|
|
Note |
|
|
The status indications "OLD" and "NEW" are irrelevant to |
|
|
the version of the firmware data. |
|
|
|
|
|
Startup Page | Display only |
|
Indicates (with an "x" sign) the active page on startup. |
|
|
Generally, the startup page is the firmware data whose status |
|
|
is "Main Operation Mode". |
|
|
The exception is when the card undergoes a reboot after a |
|
|
firmware data upload operation; in this case, the card starts |
|
|
up with the page in the "NEW" status. This is for the purposes |
|
|
of confirming the result of the upload operation. If you reboot |
|
|
again, the card starts up with the page in the "Main Operation |
|
|
Mode" status. |
|
|
To set the updated page as the active page on startup, you |
|
|
must change its firmware status to "Main Operation Mode". |
|
|
|
|
|
Operation | Not applicable | Empty, |
Specifies whether to set the page (selected with the |
| Main Operation Mode |
|
| |
parameter Select Page) as the active page on startup ("Main |
|
|
Operation Mode"), or delete the page ("Empty"). |
|
|
"Empty" is an option provided for engineer use only. |
|
|
|
|
|
Select Page | Not applicable | |
Specifies the target page of the operation selected with the |
| |
|
| |
parameter Operation. |
|
|
|
|
|
66 Programming Guide