2.2 Programming

3.Click ENTRY.

A maximum of 16 hunt patterns can be created.

4.Click OK.

You will see a confirmation screen.

Note

If your entry contains an invalid value, you will be prompted to correct your input. Enter correct values for the parameters shown in red and try again.

5.Confirm your entry and click OK.

To return to the previous screen, click CANCEL.

Parameter Descriptions

The parameters indicated with "*" must be changed while the VoIP Gateway Card is in the "STOP" status (see "2.3.1 Status Control"). The changes do not have to be followed by a reboot to become effective.

Hunt Group

Parameter & Description

Default

Value Range

 

 

 

* Port1–8

Hunt group 1

Hunt group 1 to 8

Assigns a hunt group to a VoIP gateway port.

 

 

For details, refer to "Detailed Explanations".

 

 

 

 

 

Hunt Pattern Entry

The parameters below are used to create hunt patterns.

For details, refer to "Detailed Explanations".

Parameter & Description

Default

Value Range

*

Hunt Pattern No.

No default

1 to 16

 

Specifies the number for the hunt pattern to be created.

 

 

 

When changing the current settings of an existing hunt

 

 

 

pattern, first delete the hunt pattern and then re-create with

 

 

 

new values.

 

 

 

 

 

 

*

Receive Leading Number

No default

Max. 30 digits

 

Specifies the leading digits in received numbers by which to

 

 

 

determine the hunt group to direct incoming calls.

 

 

 

For example, to direct incoming calls with numbers starting

 

 

 

with "9", specify the number "9" in this parameter. Likewise,

 

 

 

to direct incoming calls with numbers starting with "1", specify

 

 

 

the number "1".

 

 

 

However, if you want to direct incoming calls with numbers

 

 

 

starting with "950" and "951" to separate hunt groups, it is

 

 

 

necessary to make 2 hunt patterns with respective numbers,

 

 

 

"950" and "951".

 

 

Programming Guide