2.3 Maintenance

Parameter & Description

Default

Value Range

 

 

 

Password

Administrator

Max. 16 characters

Administrator-level log-in password.

 

 

 

 

 

Password (Confirmation)

No default

Max. 16 characters

Confirmation of the administrator-level log-in password.

 

 

 

 

 

Programming Auto Disconnect Time Settings

 

 

 

 

 

Parameter & Description

Default

Value Range

 

 

 

Programming Auto Disconnect Time (min) 1-30min

10

1 to 30

Specifies the time (in minutes) until programming is

 

 

automatically terminated.

 

 

If the specified period of time passes with no programming

 

 

input, programming will automatically be terminated. This

 

 

prevents problems caused by continuation of log-in status in

 

 

cases such as being unable to log out due to the sudden

 

 

failure of a PC.

 

 

 

 

 

Periodic Diagnosis Time Interval Settings

 

 

 

 

 

Parameter & Description

Default

Value Range

 

 

 

* Periodic Diagnosis Time Interval (min) 0-1440min

60

0 (no periodic

Specifies the time (in minutes) between periodic self-

 

diagnosis),

 

1 to 1440

diagnoses to test operation as described in "2.3.3 Diagnosis".

 

 

 

If failures are detected during the self-diagnosis, the card will

 

 

alert the PBX.

 

 

 

 

 

44 Programming Guide