18 I/O expander IC M62320P I2C
failure (DW & PIP)
X X
19 Guide+ I2C failure X X
20 V-chip for PIP, IC ZILOG 86130 I2C
failure (TBC)
X X
21 NV clock IC MK41T56 I2C failure
22 Flash protection (detected via
Bocma)
23 Bocma IC TDA888xx (on DW panel)
I2C communication
X X
27 Virtual Dolby error X X
30 HIP l/O-video processing error X X
31 Picnic X X
32 HOP video control/geometry X
33 8v6 X
34 Hikup protection X
35 HD interface I/O expander M62320
I2C failure
X
1. New Error codes for LCHDR
101 No Ack or response from GDE for
the transmitted message even after
maximum no. of retries
X Unrecoverable error for
transmissions
102 HCS encountered errors on MAX
RETRY consecutive received
messages
X Unrecoverable errors on
reception
103 Sony A/V Switch I2
C communication
failure
X I2C communication on
interaction with Sony A/V
switch
104 GDE non-critical error X GDE reported non-critical
error on - 1 Am Alive message
105 Change Display Config Exit did not
occur X HCS did not receive the
Display Config Exit command
From GDE within 2s from
Change Display Config Enter
command sent.
106 to
119 Reserved for future error codes X
Table 1 LCHDR error codes for US cluster