2 - 10 Users Manual
2.2.3 Sense modes
Each output channel has been provided with a set of four terminals. The inner
terminals have been marked as - V(olta
g
e) and + V(olta
g
e), while the outer
terminals have been marked as - S(ense) and + S(ense).
Each output channel can be connected to a load in two different ways:
• throu
h the +V and -V terminals, causin
the power supply to operate in
its local sense mode.
• throu
h the +V and -V and +S and -S terminals, causin
the power supply
to operate in its remote sense mode.
Local sensin
g
At delivery the sense terminals are interconnected with the volta
g
e terminals. This
is called local sensin
g
. If the volta
g
e drop across both of the wires to the load is
ne
g
li
g
ible, the volta
g
e at the load will equal the pro
g
rammed value.
- S- V+ V+ S
- S- V+ V+ S
load