5 - 10 Users Manual
5.5.2 Local and remote sensin
g
All models have the ability to sense the output volta
g
e locally or remotely. The
wires between an output channel and the connected load have a resistance,
which causes a volta
g
e drop. If the volta
g
e drop is not acceptable, remote sensin
g
must be applied.
The formula to calculate the volta
g
e drop is Vdrop = Iload x Rlead:
•Vdrop =the total volta
g
e drop of both wires
•Iload =the current throu
g
h the load
•Rlead =the total resistance of both wires between the power supply and the
load
Fi
g
ures 5.5.5 and 5.5.6 show the difference between a local and remote
connection has been indicated.
CAUTION: To prevent shock or short-circuit you must set the power supply to the standby mode before making
g
All the models and their output channels have the same terminal block (see the
followin
g
dia
g
ram). This means that all output channels have the local or remote
sensin
g
feature. The load is supplied with power (volta
g
e and/or current) throu
g
h
the output terminals -V and + V. The readback of the output volta
g
e is done
throu
g
h the input terminals -S and + S.
+S
+V
V
S
R
12lead
R
2
1lead
Rload
ST5836
Fi
g
g
lead
.