Usin
g
your Pro
g
rammable Power Supply 5 - 33
Local sensin
g
(outputs in series):
Connect the load wires to the +V terminal of output channel 1 and the -V terminal
of output channel 2, and interconnect the -V terminal of output channel 1 and the
+V terminal of output channel 2. Connectin
g
the +S of output channel 2 to the -S
of output channel 1, while removin
g
the local sense jumper between +S and +V
of output channel 2, will compensate for the volta
g
e drop across the wires from
output channel 2 to output channel 1. The followin
g
dia
g
ram shows the wirin
g
scheme.
+S
+V
V
S
+S
+V
V
S
LOAD
ST5874
+
OUTPUT 1
OUTPUT 2
Fi
g
ure 5.6.3 Local Sensin
g
with Two Outputs in Series