Usin
g
your Pro
g
rammable Power Supply 5 - 15
Example for a variable load resistance:
Required: The Vset and Iset parameter have been coupled for the selected
output channel.
•I
Set = 1A Pro
g
rammed current becomes 1A.
•V
set = 8V Pro
g
rammed volta
g
e becomes 8V.
•If R
load increases from 8 to 16Ω, then Rload > Rc, so the output channel
g
oes
into the CV mode (refer to fi
g
ure 5.5.7). This means that Vload = 8V and
Iload becomes 8V/16 = 0.5A.
•If R
load decreases from 8 to 4Ω, then Rload < Rc, so the output channel
g
oes
into the CC mode (refer to fi
g
ure 5.5.7). This means that Iload = 1A and Vload
becomes 1A x 4 = 4V.
Example for a fixed load resistance:
Required: - Fixed load resistance Rload = 10.
- Overcurrent protection disabled (OCP DIS).
- The Vset and Iset parameter have not been coupled.
power
output
+
-
load
+
-
Vset
OVPset
Iset
Vset = Volta
g
e pro
g
rammed
Iset = Current pro
g
rammed
Rload = 2 to 20 (variable)
The crossover point resistance Rc = Vset / Iset = 8.
power
output
+
-
load
+
-
Vset
OVPset
Iset
Vset = Volta
g
e pro
g
rammed
OVPset = OverVolta
g
e pro
g
rammed
Iset = Current pro
g
rammed