2.5 Setting Protocol of Dome Camera

If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol.

Consult service personnel if a dome camera is installed with device other than a keyboard controller.

S/W

 

On

Off

Function

 

 

 

 

 

 

D1

 

S4-1

Enable

Disable

Alarm

D2

 

S4-2

PAL

NTSC

NTSC/PAL

D3

 

S4-3

 

Endless

 

D4

 

S4-4

RS-422

RS-485

RS-422/RS-485

 

 

 

 

 

D5

D6

D7

Protocol

 

 

 

 

 

S5-1

S5-2

S5-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Off

Off

Fastrax, Pelco D&P, Dynacolor, Ernitec &

 

 

 

 

 

 

 

 

 

 

Philips G3 Protocol (Default)

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Off

On

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

Off

Sensormatic RS-422

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

On

On

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

Off

Off

Vicon Protocol

 

 

 

 

 

 

 

 

 

 

On

Off

On

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

On

Off

Dynacolor

 

 

 

 

 

On

On

On

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D8

D9

D10

Baud Rate

 

 

 

 

 

 

 

 

 

 

S5-4

S6-1

S6-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Off

Off

2400 bps

 

 

 

 

 

 

 

 

 

 

Off

Off

On

4800 bps

 

 

 

 

 

 

 

 

 

 

Off

On

Off

9600 bps (Default)

 

 

 

 

 

Off

On

On

19200 bps

Figure 13 – Protocol Selection Switches

On

Off

Off

38400 bps

 

 

 

 

 

 

 

 

 

 

On

Off

On

57600 bps

 

 

 

 

 

On

On

Off

115200 bps

 

 

 

 

 

On

On

On

230400 bps

 

 

 

 

 

 

 

 

 

Unless Baud rate match, universal protocol will not work.

D11

D12

Camera

S6-3

S6-4

 

 

 

 

Off

Off

Default cameras (Default)

Off

On

Reserved

On

Off

Reserved

On

On

Reserved

13