2.2 Basic Configuration of Fastrax II Dome Camera System

Power 24VAC

STP AWG #24

Alarm output

Alarm input

1 ~ 2

1 ~ 4

Sensor

Power 24VAC

Alarm input

up to 8

SirenBNC

Dome1+

Dome1–

Light

 

 

 

 

Alarm output

Monitor

 

 

 

up to 4

 

Alarm output

Alarm input

 

 

 

 

 

3 ~ 4

5 ~ 8

 

 

 

RS-485

 

 

 

 

Half Duplex mode: RX+, RX–

 

 

 

RS-422

 

 

 

 

Simplex mode: (RX+), (RX–)

 

 

BNC

Duplex mode: (TX+), (TX–), (RX+), (RX–)

 

 

 

 

J-Box (Back)

 

 

J-Box (Front)

 

Up to 128 Dome cameras including 32 alarm mode can be connected at DOME2 port.

unshielded cable

DATA2 port should be connected in case that DOME2 port or DVR port are used.

unshielded cable

Rear

Keyboard controller

Figure 4- Basic installation diagram

The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and building codes. The system should be installed according to Figures 4 through 9.