Pioneer MUH-GA20VB Performance Curves, Max. Refrigerant Piping Length, Max. Height Difference

Models: MUH-GA20VB MUH-GA25VB MUH-GA35VB

1 36
Download 36 pages 25.9 Kb
Page 11
Image 11
MAX. REFRIGERANT PIPING LENGTH

MAX. REFRIGERANT PIPING LENGTH

 

 

 

 

 

Refrigerant piping

Piping size O.D : mm

Length of connecting pipe : m

Model

 

 

 

Max. length : m

 

 

 

 

 

 

 

 

 

 

 

 

A

Gas

Liquid

Indoor unit

Outdoor unit

MUH-GA20VB -

 

 

 

 

 

 

 

 

E1

 

20

 

 

Gas 0.43

Gas 0

MUH-GA25VB -

 

 

 

 

 

E1

 

 

9.52

6.35

 

 

 

 

 

 

 

 

Liquid 0.5

Liquid 0

 

 

 

 

 

 

 

 

MUH-GA35VB -

 

 

 

 

25

 

 

 

 

 

 

 

 

 

E1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAX. HEIGHT DIFFERENCE

Height difference should be within 10m regardless of which unit, indoor or outdoor position is high.

Indoor unit

 

Refrigerant Piping

w Max. Height

Max.length

A

difference 10m

 

Outdoor unit

ADDITIONAL REFRIGERANT CHARGE(R410A : g)

Model

 

 

Outdoor unit precharged

 

Refrigerant piping length (one way)

 

 

 

 

 

 

 

 

 

 

7m

10m

15m

20m

25m

 

 

 

 

MUH-GA20VB -

 

 

650

 

 

 

 

 

E1

 

 

 

 

 

 

 

 

 

 

0

60

160

260

 

MUH-GA25VB -

 

 

 

E1

 

 

 

 

 

 

800

 

 

 

 

 

MUH-GA35VB -

 

 

 

 

 

 

360

 

 

 

 

 

 

E1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculation : Xg = 20g/m x (A-7)m

8

PERFORMANCE CURVES

MUH-GA20VB - E1

MUH-GA25VB - E1

MUH-GA35VB - E1

The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions, since operating conditions vary according to the areas where these units are installed. The following information has been pro- vided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.

(1)GUARANTEED VOLTAGE

198~264V

(2)AIR FLOW

Air flow should be set at MAX.

(3) MAIN READINGS

(1)

Indoor intake air wet-bulb temperature :

°CWB

}

 

(2)

Indoor outlet air wet-bulb temperature :

°CWB

Cooling

(3)

Outdoor intake air dry-bulb temperature :

°CDB

 

(4)

Total input:

W

} Heating

(5)

Indoor intake air dry-bulb temperature :

°CDB

(6)

Outdoor intake air wet-bulb temperature :

°CWB

(7)

Total input :

W

 

 

Indoor air wet/dry-bulb temperature difference on the left side of the chart on page 10 shows the difference between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.

11

Page 11
Image 11
Pioneer Performance Curves, Max. Refrigerant Piping Length, Max. Height Difference, MUH-GA20VB- E1, MUH-GA25VB- E1