Manuals
/
Pioneer
/
Household Appliance
/
Air Conditioner
Pioneer
MUH-GA25VB, MUH-GA35VB, MUH-GA20VB service manual
Models:
MUH-GA20VB
MUH-GA25VB
MUH-GA35VB
1
34
36
36
Download
36 pages
25.9 Kb
29
30
31
32
33
34
35
36
<
>
Troubleshooting
Specs
Parts list
Wiring Diagram
Dimension
D How to check mis-wiringand serial signal error
Disassembly Instructions
Operating Procedure
Ambient temperature˚C
Symbol
Page 34
Image 34
34
Page 33
Page 35
Page 34
Image 34
Page 33
Page 35
Contents
No. OB387
CONTENTS
SPLIT-TYPE,HEAT PUMP AIR CONDITIONERS
Wireless type Models
MUH-A09YV- E1 MUH-GA25VB- E1
TECHNICAL CHANGES
MUH-A07YV- E1 MUH-GA20VB- E1
MUH-A12YV- E1 MUH-GA35VB- E1
Refrigerant
Can R22 tools be used?
liquid
R410A tools
Description
4.Air purge
3.Refrigeration oil
5.Additional charge
PART NAMES AND FUNCTIONS
3 SPECIFICATION
ACCESSORIES
OUTDOOR UNIT
MUH-GA25VB
NOISE CRITERIA CURVES
MUH-GA20VB
MUH-GA35VB
MUH-GA25VB- E1
OUTLINES AND DIMENSIONS
MUH-GA20VB- E1 OUTDOOR UNIT
MUH-GA35VB- E1
MUH-GA25VB- E1 MUH-GA35VB- E1
WIRING DIAGRAM
MODELS WIRING DIAGRAM
MUH-GA20VB- E1 OUTDOOR UNIT
MUH-GA25VB- E1 MUH-GA35VB- E1
REFRIGERANT SYSTEM DIAGRAM
MUH-GA20VB- E1 OUTDOOR UNIT
Unit mm
MAX. HEIGHT DIFFERENCE
PERFORMANCE CURVES
MAX. REFRIGERANT PIPING LENGTH
ADDITIONAL REFRIGERANT CHARGER410A g
OUTDOOR UNIT
INDOOR UNIT
8-1.CAPACITYAND THE INPUT CURVES
Wet-and dry-bulbthermometers
MUH-GA25VB- E1
MUH-GA20VB- E1
MUH-GA35VB- E1
Ambient temperature˚C
HEAT operation
Ambient temperature˚C
Ambient temperature˚C
MUH-GA20VB- E1
MSC-GA20VB- E1
PERFORMANCE DATA COOL operation
MUH-GA20VB- E1
MSC-GA20VB- E1
CAPACITY 2.3kW SHF 0.74 INPUT 715W
MSC-GA25VB- E1
MUH-GA25VB- E1
MUH-GA25VB- E1
MSC-GA25VB- E1
CAPACITY 2.65kW SHF
MSC-GA35VB- E1
MUH-GA35VB- E1
MUH-GA35VB- E1
MSC-GA35VB- E1
CAPACITY 3.5kW SHF 0.66 INPUT 1090W
MSC-GA25VB- E1
MSC-GA20VB- E1
MUH-GA20VB- E1
MUH-GA25VB- E1
9-1.COMPULSORY DEFROSTING MODE FOR SERVICE
SERVICE FUNCTIONS
10 TROUBLESHOOTING
9-2.CHANGE IN DEFROST SETTING
10-2.Instruction of troubleshooting
MUH-GA20VB- E1 MUH-GA25VB- E1 MUH-GA35VB- E1
MUH-GA20VB- E1
A Check of outdoor unit
10-4.Troubleshooting flow
MUH-GA25VB- E1
C Check of R.V. coil
B Check of outdoor unit
C Check of R.V. coil
Serial signal error is indicated
D How to check mis-wiringand serial signal error
0.5-sec.ON, 0.5-sec.OFF
E Check of outdoor thermistor
10-5.Test point diagram and voltage
Outdoor deicer P.C. board
MUH-GA20VB- E1 MUH-GA25VB- E1 MUH-GA35VB- E1
PHOTOS
11 DISASSEMBLY INSTRUCTIONS
OPERATING PROCEDURE
MUH-GA20VB- E1 OUTDOOR UNIT
2. Removing the deicer P.C. board
OPERATING PROCEDURE
PHOTOS
Photo
4. Removing the compressor
OPERATING PROCEDURE
PHOTOS
Photo
12-1.OUTDOOR UNIT STRUCTURAL PARTS
12 PARTS LIST
MUH-GA20VB- E1 MUH-GA25VB- E1
MUH-GA35VB- E1
MUH-GA25VB- E1
Symbol
MUH-GA20VB- E1
MUH-GA35VB- E1
Page
Page
Distributed in Feb. 2005. No.OB387
Specifications subject to change without notice
New publication, effective Feb
Made in Japan