Pioneer MUH-GA35VB, MUH-GA25VB Part Names And Functions, Specification, Outdoor Unit, Accessories

Models: MUH-GA20VB MUH-GA25VB MUH-GA35VB

1 36
Download 36 pages 25.9 Kb
Page 6
Image 6
PART NAMES AND FUNCTIONS

2

PART NAMES AND FUNCTIONS

OUTDOOR UNIT

ACCESSORIES

MUH-GA20VB - E1 MUH-GA25VB - E1 MUH-GA35VB - E1

MUH-GA20VB- E1 MUH-GA25VB- E1 MUH-GA35VB- E1

Air inlet

back : MUH-GA20VB

( back and side : MUH-GA25VB ) MUH-GA35VB

Piping

Drain hose

Air outlet

<Outdoor unit: MUH type>

Drain socket

1

Drain outlet

3 OUTDOOR UNITACCESSORIES SPECIFICATION

 

 

Outdoor model

 

MUH-GA20VB - E1

 

 

Outdoor unit power supply

Single phase

 

 

230V,50Hz

 

 

 

 

 

 

Function

 

Cooling

 

Heating

Capacity

Capacity

kW

2.3

 

2.5

Outdoor air flow

K /h

0.9

1800

 

 

Dehumidification

R/h

 

 

 

Power outlet

A

 

10

 

 

Running current

A

3.00

 

2.86

Electrical

 

Power input

W

680

 

655

data

Auxiliary heater

A(kW)

 

 

 

 

 

 

Power factor

%

99

 

100

 

 

Starting current

A

 

21

 

 

Compressor motor current

A

2.76

 

2.62

 

 

Fan motor current

A

 

0.25

 

 

 

 

3.22

 

3.62

 

Coefficient of performance (C.O.P)

 

Compressor

Model

 

RN092VHSHT

resistance (at 20:)

W

C-S 6.14

 

 

Output

 

600

 

 

Winding

"

C-R 3.87

 

 

 

 

 

 

Fan

motor

Model

 

RA6V21-AD

 

Winding

"

WHT-BLK 366

 

 

 

 

 

resistance (at 20:)

 

BLK-RED 274

 

 

Dimensions WOHOD

mm

800o550o285

 

 

Weight

kg

 

32

 

 

Sound level

dB

 

47

 

remarks

Fan speed

rpm

 

745

Special

Fan speed regulator

 

 

1

capacity (R410A)

 

 

 

 

 

 

Refrigerant filling

kg

 

0.65

 

 

 

 

 

 

Refrigeration oil (Model)

cc

350

(NEO22)

 

 

Thermistor RT61 (at 0:)

k"

33.18

 

 

NOTE: Test conditions are based on ISO 5151.

 

 

Cooling : Indoor

DB27°C WB19°C

 

 

 

 

Outdoor DB35°C WB24°C

 

 

 

 

Indoor-Outdoor piping length : 5m

 

 

MUH-GA25VB - E1

 

MUH-GA35VB - E1

Single phase

 

Single phase

230V,50Hz

 

230V,50Hz

Cooling

 

Heating

 

Cooling

 

Heating

2.65

 

3.0

 

3.5

 

3.7

1.1

 

 

1.7

 

 

1902

 

1902

 

 

10

 

10

 

3.43

 

3.43

 

4.65

 

4.34

785

 

785

 

1,050

 

980

 

 

 

100

 

100

 

98

 

98

 

22

 

27

 

3.10

 

3.10

 

4.32

 

4.01

 

0.33

 

0.33

 

3.23

 

3.66

 

3.21

 

3.63

RN104VHSHT

 

RN135VHSHT

 

700

 

900

 

C-R 3.40

 

C-R 2.79

C-S 4.56

 

C-S 3.36

RA6V33-KB

 

RA6V33-KB

WHT-BLK 215

 

WHT-BLK 215

BLK-RED 307

 

BLK-RED 307

800o550o285

 

800o550o285

 

32

 

35

 

 

49

 

49

 

 

855

 

855

 

 

1

 

1

 

 

0.80

 

0.80

 

350 (NEO22)

 

620 (NEO22)

 

33.18

 

33.18

 

Heating : Indoor

DB20°C

 

 

 

Outdoor

DB 7°C/WB 6°C

 

6

Page 6
Image 6
Pioneer MUH-GA35VB, MUH-GA25VB, MUH-GA20VB service manual Part Names And Functions, Specification, Outdoor Unit, Accessories