![SERVICE FUNCTIONS](/images/new-backgrounds/38446/3844643x1.webp)
9
SERVICE FUNCTIONS
9-1. COMPULSORY DEFROSTING MODE FOR SERVICE
By short circuit of the connector JPDS and JPSG on the outdoor deicer P.C. board, defrosting mode can be accom- plished regardless of the defrost interval restriction. (Refer to
Defrost thermistor RT61 must read below
9-2. CHANGE IN DEFROST SETTING
<JRF> When the JRF wire of the deicer P.C. board is cut, the defrost interval time will be changed.
<JRG> When the JRG wire of the deicer P.C. board is cut, the defrost temperature will be changed.(Refer to
MODEL | Jumper wire | Change point | |
|
|
| |
JRF | Defrost interval time changes from 40 minutes to 15 minutes. | ||
| |||
|
| ||
JRG | Deforst start temperature changes from | ||
|
|
|
10 ![9-1. COMPULSORY DEFROSTING MODE FOR SERVICE](/images/new-backgrounds/38446/3844643xi2.webp)
TROUBLESHOOTING
10-1. Cautions on troubleshooting
1.Before troubleshooting, check the following:
1)Check the power supply voltage.
2)Check the indoor/outdoor connecting wire for
2.Take care the following during servicing.
1)Before servicing the air conditioner, be sure to turn off the main unit first with the remote controller, and then after con- firming the horizontal vane is closed, turn off the breaker and/or disconnect the power plug.
2)Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic control P.C. board.
3)When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the components.
4)When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.
Lead wiring | Housing point |
3.Troubleshooting procedure
1)First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality. To make sure, check how many times the abnormality indication is flashing on and off before starting service work.
2)If the electronic control P.C. board is supposed to be defective, check the copper foil pattern for disconnection and the components for bursting and discoloration.
3)When troubleshooting, refer to
22