Pitco Frialator L22-306 4.4.8Fill Done Input, 4.4.9Exit Diagnostic Menu, 4.5Ready Level

Models: L22-306

1 28
Download 28 pages 2.26 Kb
Page 15
Image 15
4.4.8Fill Done Input:

Solstice I12 Water Cooker Computer Service

Part #60153301

4.4.8Fill Done Input:

Press the product key 8. Display will show state of the Fill Done input [FD xxx], where xxx is ON or OFF. Product key 8 indicator shows the ON or OFF state of the input.

4.4.9Exit Diagnostic Menu

To exit diagnostic menu, Press the

key. Display will return to [SERVICE]. Other service

menu items may be selected for changes.

To return to programming press the

settings can be made in section 2.

key again. Display will show [PROGRAM]. Other

To return to normal operations, press the

displays: [HEATING] or [READY].

key again. Display will show one of the normal

4.5Ready Level

With display showing [SERVICE], press product key 6.

Display shows [READY nn], where “nn” is the value, in degrees below set temperature that the READY message is displayed. To change this value, use the location keys for numeric entry of a new value. Factory default value is 10°F.

Press the

key. Display now shows [SERVICE].

4.6Temperature Operating Range

Forces the control to display the range of temperatures that may be set by operators.

With display showing [SERVICE], press product key 7.

Display shows [RANGE 1] [150 230]. No adjustments are permitted here. This is an

information display only. Press the

key. Display returns to [SERVICE].

4.7More Service Menu Entry

With display showing [SERVICE], press product key 8.

Display now shows

.

Location keys will illuminate where adjustments are permitted; all other keys are inactive. The following section details each product key function in the More Service Menu.

4.7.1Cook Now

Should operators be forced to acknowledge a Cook Done Alarm before starting another cook? This setting forces that requirement. Factory default value is OFF.

L22-306 Rev 0

15

Page 15
Image 15
Pitco Frialator L22-306 4.4.8Fill Done Input, 4.4.9Exit Diagnostic Menu, 4.5Ready Level, 4.6Temperature Operating Range