Pitco Frialator L22-306 service manual 4.7.9Standing Pilot Toggle, To Exit More Service Menu

Models: L22-306

1 28
Download 28 pages 2.26 Kb
Page 18
Image 18
4.7.9Standing Pilot Toggle

Solstice I12 Water Cooker Computer Service

Part #60153301

4.7.9Standing Pilot Toggle

For some applications, it is desirable to maintain the gas pilot flame when the appliance is OFF. Heat from the pilot keeps the vat warmer for quicker start-ups in the morning. Default setting for standing pilot is off.

Note: Heat Demand Profile (section 4.8.3) must be set to Generic 1, or T-stat. Standing Pilot toggle has no effect in any other setting.

With display showing [MORE] [SERVICE], press key

. Display will show [STANDING]

[PILOT n], where “n” is ON or OFF. Use key

to toggle value, then press the

to

save choice. Display returns to [MORE] [SERVICE].

 

 

4.7.10 To Exit More Service Menu

 

 

 

With display showing [MORE] [SERVICE], press the

key. Display returns to [SERVICE].

Continue with Level 2 programming in section 4 (display showing [SERVICE]), or continue.

4.8To Exit Programming Level 3

With display showing [SERVICE], press the

with changes in section 2, or continue.

key. Display will show [PROGRAM]. Continue

To return to normal operations, press the

displays: [HEATING] or [READY].

key again. Display will show one of the normal

18

L22-306 Rev 0

Page 18
Image 18
Pitco Frialator L22-306 service manual 4.7.9Standing Pilot Toggle, To Exit More Service Menu, 4.8To Exit Programming Level