Pitco Frialator L22-306 service manual 6Other Displays

Models: L22-306

1 28
Download 28 pages 2.26 Kb
Page 21
Image 21
6Other Displays:

Solstice I12 Water Cooker Computer Service

Part #60153301

6Other Displays:

Open probe detection is standard on all Pitco controls. If probe is detected open, normal heating and cooking activities are suspended.

This display warns operators that the vat temperature has exceeded set temperature by +20°F (+11°C), or an absolute maximum of 240°F (156°C). This display does not show the status of the mechanical high limit switch.

This message indicates that the drain valve has been opened. The vat is assumed to be empty by the controller. Normal heat control activities are suspended. To restore to normal operation, close the drain valve. Display will show [TURN OFF].

Turn controller off, and refill the vat. Continue with normal operations at section 1.

This message indicates that the heating system failed to respond. Typically, the high temperature limit switch has tripped and is in need of resetting. On gas fired appliances, this message will display if the pilot fails to light or is detected marginal by the ignition module.

This message indicates a shorted probe. If probe is detected as a short circuit, normal heating and cooking activities are suspended.

This message appears when the tank fails to fill within a set period of time. Check that the water supply line is turned ON. To restore to normal operation, turn the control OFF then ON again. While the tank is (re)filling, heat is disabled.

L22-306 Rev 0

21

Page 21