Solstice I12 Water Cooker Computer Service
Part #60153301
key. Display returns to [FACTORY].
5.4Diagnostic Menu Entry
Same as section 4.5 except [FACTORY] is displayed instead of [SERVICE].
5.5Ready Level
With display showing [FACTORY], press product key 6.
Display shows [READY nn], where “nn” is the value, in degrees below set temperature that the READY message is displayed. To change this value, use the location keys for numeric entry of a new value.
Press the | key. Display now shows [FACTORY]. |
5.6Operating Temperature Range
With display showing [FACTORY], press product key 7. This forces the control to display the range of temperatures that may be set by operators.
Display shows [RANGE 1] [150 230]. No adjustments are permitted here. This is an
information display only. Press the |
key. Display returns to [FACTORY].
5.7High Limit Alarm Value
Pressing product key 8 forces the control to display the temperature above set temperature, the high limit alarm will sound. This is a display only value, no changes can
be made through the keypad. Press the
key. Display returns to [FACTORY].
Factory default value is 20°F, or 240°F absolute, whichever is less. This value can only be
changed by factory download at Pitco.
5.8Test On/Off
With display showing [FACTORY], press product key [10/0].
Display shows [TEST xx], where “xx” is ON or OFF. If ON is selected, temperatures displayed by the controller are probe tip temperatures unaltered by values set in section 4.1, or 5.1. For normal operations, this setting should remain OFF.
To change this value, use product key
to toggle choice (ON or OFF).
Press the |
key. Display now shows [FACTORY].
5.9To Exit Factory Menu (Level 4):
To exit Factory Programming, press the | key. Display will show [PROGRAM]. Continue with |
settings in section 2 or 3, or exit in the next step.
To return to normal operations, press the | key again. |
Display will show one of the normal displays: [HEATING] or [READY].
20 |