5.4Diagnostic Menu Entry

Solstice I12 Water Cooker Computer Service

Part #60153301

key. Display returns to [FACTORY].

5.4Diagnostic Menu Entry

Same as section 4.5 except [FACTORY] is displayed instead of [SERVICE].

5.5Ready Level

With display showing [FACTORY], press product key 6.

Display shows [READY nn], where “nn” is the value, in degrees below set temperature that the READY message is displayed. To change this value, use the location keys for numeric entry of a new value.

Press the

key. Display now shows [FACTORY].

5.6Operating Temperature Range

With display showing [FACTORY], press product key 7. This forces the control to display the range of temperatures that may be set by operators.

Display shows [RANGE 1] [150 230]. No adjustments are permitted here. This is an

information display only. Press the

key. Display returns to [FACTORY].

5.7High Limit Alarm Value

Pressing product key 8 forces the control to display the temperature above set temperature, the high limit alarm will sound. This is a display only value, no changes can

be made through the keypad. Press the 5.5Ready Level5.6Operating Temperature Range5.7High Limit Alarm Valuechanged by factory download at Pitco.5.8Test On/Off5.9To Exit Factory Menu (Level 4):

key. Display returns to [FACTORY].

Factory default value is 20°F, or 240°F absolute, whichever is less. This value can only be

changed by factory download at Pitco.

5.8Test On/Off

With display showing [FACTORY], press product key [10/0].

Display shows [TEST xx], where “xx” is ON or OFF. If ON is selected, temperatures displayed by the controller are probe tip temperatures unaltered by values set in section 4.1, or 5.1. For normal operations, this setting should remain OFF.

To change this value, use product key

to toggle choice (ON or OFF).

Press the

key. Display now shows [FACTORY].

5.9To Exit Factory Menu (Level 4):

To exit Factory Programming, press the

key. Display will show [PROGRAM]. Continue with

settings in section 2 or 3, or exit in the next step.

To return to normal operations, press the

key again.

Display will show one of the normal displays: [HEATING] or [READY].

20

L22-306 Rev 0

Page 20
Image 20
Pitco Frialator L22-306 5.4Diagnostic Menu Entry, 5.5Ready Level, 5.6Operating Temperature Range, 5.8Test On/Off