5.10.4.HOLD PRE-ALARM

Hold Pre-Alarm is a timer setting that is used to warn operators that the Hold Time is about to expire. To use Hold Pre-Alarm, time value must be a non-zero value, and must be set to a value less than Hold Time. Default value is zero, meaning the Hold Pre-Alarm is inactive.

Display is showing [nPA mm:ss] [TIME] where “n” is the key number, PA means Pre-Alarm, and “mm:ss” is minutes and seconds.

Use the product keys for numeric entry to adjust the current setting.

Press the [Clock] key to save cook time and continue setup for this product key. Note: Value entered for Hold pre-alarm time is the hold time minus the pre- alarm time. Example: 15:00 hold time with a 5:00 prealarm time, the value you enter would be 10:00 minutes.

Display will again return to [SELECT] [TIME]. Repeat steps from 1 to make changes to any other product keys or continue.

5.11.TO EXIT LEVEL 1 PROGRAMMING:

Display shows [SELECT] [TIME]. Continue to make changes or exit here in next step. Press the [P] key. Display shows [PROGRAM]. To exit Level 1 programming, press the [P] key again. Displays will show [HEATING], [MELT] [LIQUID (or SOLID)], or [READY].

5.12.TO ENTER PROGRAMMING LEVEL 2 (FOR THE STORE MANAGER)

The display must show [PROGRAM] from (See section 4.8 “To Enter Programming Level 1” (For the Store Manager). to change these options. When the product key

[0]is pressed, the display will show [SELECT] [OPTIONS]. Indicator lights above product keys will illuminate to represent options that may be changed. Each option listed below uses the product key [0] to toggle or scroll through available choices in the display. When the correct value is displayed, press the [P] key to save choice. will again return

to [PROGRAM] for another option selection.

0

The display

5.13.FAHRENHEIT OR CELSIUS DISPLAY:

The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F. With display showing [PROGRAM], press the product key [0]. Display shows [SELECT] [OPTIONS].

Press product key 1, display shows [DEGREE n] [F OR C], where “n” is the current setting.

Use the product key [0] to scroll through choices (F or C). Press [P] key to save choice. Display shows [PROGRAM].

1

5.14.PASSWORD CHANGE OR REQUIRED?

With factory settings, an operator password is not required to enter programming Levels 1 and 2. The password may be activated or changed in this section.

With display showing [PROGRAM], press the product key [0]. Display will show

2

[SELECT] [OPTIONS].

 

 

Press product key 2, display shows [SET PASS] [NEW PASS]. Use the product key

 

[0]to scroll through choices [NO PASS] or [PASS REQ]. Press [P] key to save choice.

If [NO PASS] is selected Display returns to [PROGRAM].

If [PASS REQ]. is selected, display will show [PASSnnnn] [NEW PASS] to prompt for new password. Displayed value “nnnn” is the current password. Use the product keys for

numeric entry to change password. Press [P] key to save choice. Display shows [PROGRAM].

Note: The factory default password (6684) will always work even if a different password is selected above.

22

L20-407 rev.1 (3/14)