INSTALLATION & OPERATIONAL SGLV MANUAL

13.6.TROUBLESHOOTING CHARTS

13.6.1. FRYER TROUBLESHOOTING CHART

Problem

Probable Causes

Corrective Actions

 

No power to appliance.

Check main building power supply.

 

Controller not turned on.

Turn on controller.

Controller does

Power Cord loose or not

Connect power cord.

connected.

not activate.

 

Main circuit breaker to

Reset circuit breaker

 

 

appliance has tripped.

 

 

 

Appliance fuse has blown.

Contact Authorized Service Company.

 

High temperature limit has

Allow appliance to cool and reset High

Controller is on

tripped.

temperature limit.

and appliance will

SCBS thermal limit switch has

Depress button on thermal limit switch to reset. If

not heat up.

problem continues, Contact Authorized Service

 

tripped.

Company.

 

 

Appliance will not

Faulty temperature probe.

Contact Authorized Service Company.

maintain

 

 

temperature

Faulty High temperature limit.

Contact Authorized Service Company.

properly.

 

 

 

Computer display

 

 

shows off and can

Faulty computer

Contact Authorized Service Company.

not be turned on.

 

 

 

 

 

13.6.2. FILTER TROUBLESHOOTING CHART (IF EQUIPPED)

Problem

Probable Causes

Corrective Actions

Filter pump does

Filter pump circuit breaker or

Reset circuit breaker/ allow motor to cool, press

not activate.

thermal overload has tripped.

RED reset button on motor.

Oil/shortening is

Dirty filter paper

Change filter paper.

returning to the

Strainer cap dirty

Remove strainer cap and clean.

tank slowly or not

Filter pan not pushed in

Push filter pan in.

at all.

completely.

 

Excessive air

Pickup tube screen not tight.

Tighten pickup tube screen cap.

Pickup tube screen cap

Locate and install pickup tube screen cap.

bubbles are in the

missing

oil being returned

 

 

Filter pan not pushed in

 

to the tank.

Push filter pan in to complete connection.

completely

 

 

Drain valve is

Blue drain valve handle not

Verify that drain valve handle is completely

closed, but the

completely closed

closed.

computer

 

 

controller still

Improperly adjusted or

Contact Authorized Service Company.

displays

defective drain switch.

 

“DRAINING”

 

 

36

L20-407 rev.1 (3/14)

Page 36
Image 36
Pitco Frialator SSHLV14 Troubleshooting Charts Fryer Troubleshooting Chart, Filter Troubleshooting Chart if Equipped