6.2.1Room Ambient Contrast
Minimum Contrast of the display under room ambient lighting conditions of 1076 LUX [100 fC] direct incident illumination, is > 90:1. Reference
6.2.2High Ambient Contrast
Minimum Contrast of the display in a diffuse
6.3Display Uniformity
Luminance Uniformity (UL) measured within 30 mm from edge of the display image area is + 40% of the luminance measured at the center of the display screen.
6.4Display Chromaticity
The metric used for color coordinate determination is the CIE 1976 UCS (Uniform Chromaticity Scale) u’, v’ system.
Color determination is performed normal to the display in a dark room environment with ambient light conditions less than 10 LUX [1fC] incident illumination.
The measured u’, v’ color coordinates at room temperature for
Color | u? | v? | Perceived Color |
|
|
|
|
Red | 0.449 | 0.517 | Red |
Blue | 0.144 | 0.299 | Blue |
Green | 0.142 | 0.559 | |
White | 0.215 | 0.489 | Warm White |
White color is concentrated around 5600oK color temperature.
6.5LCD Panel - Physical Image Characteristics
∙The Monitor incorporates a matrix display with the following features:
∙ | LCD Size: | 307.5mm [12.11in] diagonal |
∙ | Active Area: | 246.0mm [9.69in] by 184.5mm [7.26in] |
∙ | Pixel Format: | 800 (H) x 600 (V) (1 full color pixel = R + G + B dots) |
∙ | Pixel Pitch: | 0.3075mm [0.012in] horizontal x 0.3075mm [0.012in] vertical |
∙ | Pixel Arrangement: | R,G,B vertical stripe |
Title: Product Specification: LC12 | Page 17 of 24 |
Document Number: | Revision: A |