∙ Electromagnetic Immunity | EN 50082 part 1:1992 |
8.3RFI Emission Certification
The Monitor is certified to the following emissions standards when installed in customer product configuration:
∙FCC, Part 15, Paragraph 15.107(b) and 15.109(b), Class A RFI emissions standard.
∙EN 55022 Class A: 1994 ? Limits and measurements of radio interference characteristics of information technology equipment.
∙ | IEC 1000 | Current Harmonic Tests |
∙ | IEC 1000 | Voltage Fluctuation and Flicker Tests |
8.4System Transient Disturbance Requirements
The Monitor meets the following system transient disturbance requirements:
8.4.1Electrostatic Discharge
The Monitor performs normally when subjected to static electricity discharges from persons touching the external surfaces of the Monitor. Performance is verified by testing according to EN
8.4.2Electromagnetic Energy Susceptibility Requirements
The Monitor performs normally in an electromagnetic field with a strength of 10- volts per meter from 10 KHz to 1 GHz. (REF CISPR 22).
The Monitor with appropriate cables is designed to comply with applicable EMC and Safety standards as noted in sections 2.31 and 2.3.2.
8.5Labeling
Where applicable, the Monitor complies with IEC 60417 – Graphical Symbols for Use on Equipment
8.6Color Coding
Where applicable, the Monitor complies with ISO 3864 – Safety colors and Safety Signs
9.0Reliability
9.1Design Workload
The Monitor is capable of operating 24 hours a day, 365 days a year under the specified environmental conditions per section 3.1.
Title: Product Specification: LC12 | Page 20 of 24 |
Document Number: | Revision: A |