2.11 Button Board

The button board controls the user controls noted in Section 6.1 LCD Controller Board Controls It can be removed or mounted in another area after initial adjustments are made.

3 Environmental

3.1Temperature and Humidity

The LC1200R withstands operating and storage environmental conditions listed in Table 2.

Table 2

 

General Operating

Shipping and Storage

Comments

 

 

 

 

Temperature

0°C to 60°C

-20°C to 60°C

Note 2,3,4,5

 

[32°F to 140°F]

[-4°F to 140°F]

 

Relative

Note 1

Note 1

Without

Humidity

 

 

Condensation

Tair is defined as ambient air temperature surrounding the LC1200R.

Note 1:

Tair <

32°C

: 95% RH maximum.

 

Tair >

32°C

: Absolute humidity content not to exceed 100% at 32oC.

Note 2:

Tair @

-20°C

< 48 hours

 

Tair @

60°C

< 168 hours

Note 3: Slight background color changes are allowed depending on ambient temperature. This phenomenon is reversible.

Note 4: High temperature operation assumes the use of an enclosure that properly directs the fan airflow

Note 5: Upper operating temperature limit of 60°C is without solar loading.

Reference to "room ambient" is interpreted as 20°C - 25°C [68°F°-77°F] and applies throughout this specification unless otherwise noted.

For product reliability predictions, the assumed temperature profile is:

Table 3

Operating Time

Temperature

 

 

5%

0°C [32°F]

 

 

90%

30°C [86°F]

 

 

5%

60°C [140°F]

 

 

LC1200R User’s Guide 021-0183-00 Rev A

9 of 29

Page 9
Image 9
Planar LC1200R user manual Environmental, Button Board, Temperature and Humidity