Mechanics of Programming

Data Field Programming Procedures (You must use a 2-line Alpha display keypad)

Task

Procedure

Entering Program Mode

A) Press both [∗] and [#] at the same time within 50 seconds after power is applied

 

to the control, OR

 

B) After power-up, enter [Installer code (4-1-1-2)] + 8 0 0.

 

(method “B” is disabled if you exit the program mode using ∗98)

Go to a Data Field

Press [∗] + [Field Number] (for example, ∗21).

 

A display of “EE” or “Entry Error” means you have entered a nonexistent field.

 

Simply re-enter [∗] plus a valid field number.

 

 

Entering Data

When the desired field number appears, simply enter the digits required. The

 

keypad beeps three times after the last digit is entered and automatically displays

 

the next data field in sequence.

 

If entering less than the maximum digits available (e.g., phone number field),

 

enter the desired digits, then press [∗] to end the entry.

 

 

Review a Data Field

Press [#] + [Field Number]. Field data is displayed, but no changes can be made.

Deleting an Entry

Press [∗] + [Field No.] + [∗] (applies only to phone number, account number, and

 

pager character fields).

Menu Mode Programming (56, *57, 58, 79, 80, 81, 82)

Entering Menu Mode

Press [∗] + [Menu Mode No.] (for example, ∗56) while in Program Mode. The

 

Alpha display keypad displays the first of a series of prompts.

 

After making the appropriate entry, press the [∗] key to accept the entry and

 

continue to the next prompt.

Loading Factory Defaults/Initializing for Download

To Load Default Entries

Press ∗97 while in Program Mode. This resets all data fields to the default

 

values shown on the Program Form. Use ∗97 only if you wish to return to the

 

original factory-programmed defaults. Do not press ∗97 to load defaults if any

 

programming has been done previously—data already programmed into the

 

system will be changed!

To Initialize Download ID

Press ∗96 while in Program Mode. This initializes the system for

 

downloading and resets all the subscriber account numbers and CSID.

Exiting the Programming Mode

Prevent installer code reentry

Press ∗98. Exits Programming Mode and prevents re-entry by:

 

Installer Code + [8] + [0] + [0]. To enter the programming mode if ∗ 98 was

 

used to exit, you must first power the system down. Then power up again,

 

and press [∗] and [#] at the same time, within 50 seconds of powering up.

 

See field *88 for other Program mode lockout options.

Allow installer code reentry

Press ∗99. Exits Program Mode and allows re-entry by method A or B above.

3-5