These fields must be enabled for Residential Fire, UL Residential Burglar Alarm, and UL Commercial Burglar Alarm installations.

Installation Instructions

Wireless Receiver, Transmitters, and Wireless Keys (keyfobs)

Receiver: Set the receiver’s address to “00” using its DIP switches, then set the following options: *22 RF Jam Option

*24 RF House ID Code (if using wireless keypads)

*67 Transmitter Low Battery Report Code

*75 Transmitter Low battery restore report code

*173 RF Reporting Options

Transmitters: Use *56 or *58 Zone Programming Menu modes to program zone information and enroll transmitters.

Wireless Keys: Use Wireless Key Programming Templates section of the *58 Zone Programming Menu mode to program zone information and enroll each button of the wireless keys used. Once a wireless key is enrolled, it must be assigned to a user before it becomes active. See Adding/Deleting Security Codes section for procedure.

Pager Programming

The system can send various reports to a pager.

To program pager reporting, do the following:

1.Enter the appropriate information in the following data fields: *160, Pager Phone Number

*161, Pager Prefix Characters *162, Pager Reporting Options

2.Enable Pager Delay, if desired, in field *172

3.Make sure appropriate user open/close pager reports are enabled using the user attribute command (see Security Codes, Assigning Attributes in Section 6. System Communication and Operation).

4.If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master code + [#] [6] [4] then select event type “03”). System must be armed for the Latchkey report to be sent.

5.If using a function key to manually send a message to a pager, see Function Keys paragraph on the next page.

6.If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones associated with each pager (zone lists 9).

Function Keys

To assign functions to the function keys, use *57 Function Key menu mode.

To assign emergency key functions (function key option “00”), first program the respective emergency zone number (95 for “A” key, 96 for “C” key, 99 for “B” key) with the desired zone type using *56 Zone Programming mode, then use *57 Function Key menu mode to assign the desired key.

If using a function key to activate a relay action (*57 Menu mode key function 07), use *79 Menu mode to map the output, and use *80 Menu mode to define the output’s action; select system operation type “66.”

If using a function key for a user macro, use *57 menu mode to activate the desired key, then define the actual macro functions using the user code + [#] + [6] [6] command.

Output Devices

To program a device for manual activation (user code + [#] [7] / [#] [8] + 2-digit device number) or for scheduled automatic activation, simply map the device using *79 Menu mode.

To program a device to automatically activate upon a system event (or function key), use *79 Menu mode to map the device, then use *80 Menu mode to define the automated device action.

If the device action is based on more than one zone, use *81 Zone List menu mode to assign the zones.