User Security Codes

Installation Instructions

User Security Codes

The system supports up to 16 security codes, which can each be assigned one of 4 authority levels. The authority level determines the functions each code can perform as follows:

Authority Levels (authority levels can be assigned to users 3-16 only; users 1 and 2 cannot be changed)

Level

User No.

Functions

Installer

01

(default=4112) perform all security functions except can disarm only if used to

 

 

arm; can enter program mode; can change System Master code; cannot assign any

 

 

other user codes

System

02

(default 1234) only one system master code per system; can perform all

Master

 

security functions, add/delete users, change system master code, view event log, set

 

 

system clock, program keypad macro, program scheduled events, activate output

 

 

devices (triggers/relays)

 

 

 

0-User

03-16

perform security functions (arm, disarm, etc.) only; cannot add/delete

 

 

users, view event log, set system clock or program scheduled events

 

 

 

1-Arm Only

see “user”

arm system only

 

 

 

2-Guest

see “user”

can disarm the system only if it was used to arm the system

3-Duress

see “user”

performs security functions, but also silently sends a duress message to the central

 

 

station; reports as duress code user number.

 

 

 

Refer to the user guide for procedures on adding/deleting security codes and changing attributes. The following is a brief description of how to add user codes.

Changing the System Master code...

Using Installer code: Installer code + [8] + 02 + new code

Using current System Master code: System Master code + [8] + 02 + new code + new code again

Adding a User Code: Master code + [8] + 2-digit user no. + user’s code

Deleting a User Code: Master code + [8] + 2-digit user no. + [#] [0]

Assigning Attributes: Master code + [8] + 2-digit user no. + [#] [attribute no.] + value

Attributes:

Values

 

1 =

Authority Level 0-3 (see Authority Level table above)

2 =

Access Group 0-8 (0 = not assigned to a group)

3 =

Not Used

4 =

RF Zone No.;assigns user number to button type zone (keyfob) for arm/disarm.

 

(keyfob must be enrolled in system first; see Wireless Key Templates section)

5 =

Open/Close Paging; 1 for yes, 0 for no

Setting the Real-Time Clock

1.Setting the Real-Time ClockDISARMEDTIME/DATE SAT 04:04PM 10/17/00TIME/DATE SAT 04:04P2000/10/17Manual backgroundManual backgroundManual backgroundManual background +[#] + [6] [3]

(Security Code)

2.Press [∗] when the time/date is displayed.

A cursor appears under the first digit of the hour.

To move cursor ahead, press []. To go back, press [#].

Enter the 2-digit hour and 2-digit minute setting.

Press [1] for PM or [2] for AM.

Enter the last two digits of the current year.

Enter the 2-digit month and 2-digit day setting.

3.To exit, press [∗] when cursor is at the last digit, or wait 10 seconds.

Alpha Display:

DISARMED

READY TO ARM

TIME/DATE SAT 04:04PM 10/17/00

Current time display

TIME/DATE SAT 04:04P2000/10/17

Time/date editing display

6-4

Page 56
Image 56
Honeywell Ademco Security Systems, VISTA-10P User Security Codes, Setting the Real-TimeClock, Disarmed Ready To Arm