Programming Overview

S E C T I O N 3

Programming Overview

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

About Programming

You can program the system at any time, even at the installer's premises prior to the actual installation. Programming can also be performed remotely from the installer’s office/home, using an IBM personal computer, a modem, and Compass downloading software.

The following is a list of the various Programming modes used to program this system:

Programming Mode…

Used to …

Data Field Programming

Program basic data fields used for setting the various system options.

 

 

Most of the data fields in this system have been programmed for specific

 

 

default values. However, some fields must be programmed for each particular

 

 

installation to establish its specific alarm and reporting features.

∗56 Zone Programming

Assign zone characteristics, report codes, alpha descriptors, and serial

 

 

numbers for 5800 RF transmitters.

∗57 Function Key Programming

Program each of the four alphabet function keys to perform one of several

 

 

system operations.

∗58 Zone Programming

Assign zone attributes similar to ∗56 mode, but provides a faster

(Expert Mode)

programming procedure and is intended for those more experienced in

 

 

programming controls of this type.

∗79

Output Device Mapping

Assign device address of the 4204 Relay module and map the specific relays

∗80

Output Definitions

Define up to 12 output definitions which can control the output relays mapped

 

 

using *79 Output Device Mapping mode.

∗81

Zone List Programming

Create Zone Lists for relay zones, chime, night-stay, cross zones, and pager

 

 

zones.

∗82

Alpha Programming

Create alpha descriptors for easy zone identification.

Scheduling Mode (code + [#] +64)

Create schedules to automate various system functions.

Keypads

Keypads are identified by predefined addresses (starting at address 16) as follows:

Address

Keypad

Program Field

 

 

 

 

 

16

keypad 1

• always enabled, all sounds enabled.

NOTE: First keypad is address 16.

 

 

 

 

17

keypad 2

• data field *190

 

18

keypad 3

• data field *191

 

19

keypad 4

• data field *192

 

20

keypad 5

• data field *193

 

 

 

 

 

21

keypad 6

• data field *194

 

22

keypad 7

• data field *195

 

23

keypad 8

• data field *196

 

To enable keypads:

1.Set desired address at keypad (refer to keypad’s instructions for setting the address).

2.Use data field program mode to enable keypad addresses and enable sound options in fields *190- *196 as shown in the table above.

3.Set the following keypad-related data fields as required by the installation: *21 Quick Arm Enable; *23 Forced Bypass; *84 Auto STAY Arm

3-1