S E C T I O N 3
Programming Overview
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About Programming
You can program the system at any time, even at the installer's premises prior to the actual installation. Programming can also be performed remotely from the installer’s office/home, using an IBM personal computer, a modem, and Compass downloading software.
The following is a list of the various Programming modes used to program this system:
Programming Mode… | Used to … | |
Data Field Programming | Program basic data fields used for setting the various system options. | |
|
| Most of the data fields in this system have been programmed for specific |
|
| default values. However, some fields must be programmed for each particular |
|
| installation to establish its specific alarm and reporting features. |
∗56 Zone Programming | Assign zone characteristics, report codes, alpha descriptors, and serial | |
|
| numbers for 5800 RF transmitters. |
∗57 Function Key Programming | Program each of the four alphabet function keys to perform one of several | |
|
| system operations. |
∗58 Zone Programming | Assign zone attributes similar to ∗56 mode, but provides a faster | |
(Expert Mode) | programming procedure and is intended for those more experienced in | |
|
| programming controls of this type. |
∗79 | Output Device Mapping | Assign device address of the 4204 Relay module and map the specific relays |
∗80 | Output Definitions | Define up to 12 output definitions which can control the output relays mapped |
|
| using *79 Output Device Mapping mode. |
∗81 | Zone List Programming | Create Zone Lists for relay zones, chime, |
|
| zones. |
∗82 | Alpha Programming | Create alpha descriptors for easy zone identification. |
Scheduling Mode (code + [#] +64) | Create schedules to automate various system functions. |
Keypads
Keypads are identified by predefined addresses (starting at address 16) as follows:
Address | Keypad | Program Field |
|
|
|
|
|
16 | keypad 1 | • always enabled, all sounds enabled. | NOTE: First keypad is address 16. |
|
|
|
|
17 | keypad 2 | • data field *190 |
|
18 | keypad 3 | • data field *191 |
|
19 | keypad 4 | • data field *192 |
|
20 | keypad 5 | • data field *193 |
|
|
|
|
|
21 | keypad 6 | • data field *194 |
|
22 | keypad 7 | • data field *195 |
|
23 | keypad 8 | • data field *196 |
|
To enable keypads:
1.Set desired address at keypad (refer to keypad’s instructions for setting the address).
2.Use data field program mode to enable keypad addresses and enable sound options in fields *190- *196 as shown in the table above.
3.Set the following