Configurable Zone Type Programming Fields
The system allows you to define a custom zone type, based on the options described below. This configurable zone types can be programmed via the downloader or from a keypad using data fields
UL installations: Do not configure zones as fire alarm or UL burglar alarm zones.
| FIELD |
|
| TITLE and EXPLANATION |
|
|
|
|
|
|
|
|
|
|
| Configurable Zone Type 90 |
|
| *182 |
|
|
| |
|
|
|
| Enter the appropriate value for each entry, |
|
|
|
|
| value for each entry, add the values of the selected options in each of the entry’s columns shown in the |
|
|
|
|
| respective chart (one option per column). For example, to program entry 2 for “alarm response to |
|
|
|
|
| short,” “auto restore on,” but not a “vent zone,” enter 5 (“1” for alarm short + “4” for auto |
|
|
|
|
| “0” for vent |
|
|
|
|
|
|
|
|
|
|
| Zone Type 90 Report Codes |
|
| *183 |
|
|
| |
|
|
|
| Enter the desired |
|
to this zone type.
Press [∗] to accept and continue.
Important Notice on Report Codes: To avoid confusion at the central station, it is recommended that existing Contact ID® codes be used with configurable zone types whenever possible. See list in System Communication section and/or check with the central station for a complete list of Contact ID® report codes. If none of the codes are suitable, choose a code in the reserved range of
Configurable Zone Type Options
Auto Restore (entry 2) | Faults on zones set for this option are cleared; restore messages sent upon |
| restoral of faults. |
|
|
Vent Zone (entry 2) | Zones set for this option are ignored if faulted when arming the system, but are |
| protected if the zone is later restored (e.g., an open window can be ignored when |
| arming, but if the window is later closed, it will be protected; opening the |
| window again causes an alarm.) |
Bypass Disarmed (entry 4) | Zones set for this option can be bypassed only while the system is disarmed. |
Bypass Armed (entry 4) | Zones set for this option can be bypassed when the system is armed or |
| disarmed. |
Dial Delay (entry 6) | Alarms on zones set for this option participate in dial delay central station |
| reporting, if system dial delay enabled in field *50. |
|
|
Fault Delay (entry 6) | Faults on zones set for this option are delayed by the time set in field *87. Do |
| not use this option if using entry/exit delay for this zone type. |
Faults Display (entry 7) | Selects how faults on zones set for this zone type are displayed. |
Power Reset/Verification | Selects whether the system resets power (when user enters code + OFF), and |
(entry 7) | whether the system performs alarm verification (see description for zone type |
| 16 in Programming Overview section) when a fault occurs on these zones. |
Use Entry Delay (entry 8) | Selects whether to use the system’s entry delay times. |
Use Exit Delay (entry 8) | Selects whether to use the system’s exit delay time. |
Interior Type (entry 8) | Zones set for this option are treated same as standard zone type 4 (bypasses |
| when armed STAY, faults displayed). |
|
|
Alarm Sounds (entry 9) | Selects the type of alarms sound for zones set for this zone type. |
|
|
Bell Timeout (entry 9) | Alarm sounding on zones set for this option remain for the duration set in fields |
| *32/*33. |
|
|
Fire Zone (entry 9) | Zones set for this option respond in the same manner as if programmed for zone |
| type 9. Do not set fire zones to respond as a “fault” in entries |
Trouble Sounds (entry 10) | Selects the type of trouble sounds for zones set for this zone type (periodic beeps |
| = once every 30 seconds; trouble beeps = rapid beeping). |
|
|
Chime Enable (entry 10) | Zones set for this option cause a chime when Chime mode is on. |
|
|