FIELD

 

 

TITLE and EXPLANATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PABX Access Code

 

 

*40

 

 

 

 

 

 

 

Enter the PABX code, if used. To clear entries from field, press ∗40∗. If fewer than 6 digits need to be

 

 

 

 

 

entered, exit by pressing [∗], which advances to the next field.

 

 

 

 

 

Call Waiting: If the subscriber’s phone service has “call waiting” (and is not using PABX), enter “*70”

 

 

 

 

 

(“# + 11”) plus “# + 13” (pause) as the PABX entry to disable “call waiting” during control panel calls. If

 

 

 

 

 

the subscriber does not have “call waiting” and is not using PABX, make no entry in this field.

 

 

 

 

 

Important: 1. The call waiting disable feature cannot be used on a PABX line. 2. Using Call Waiting

 

 

 

 

 

Disable on a non-call waiting line will prevent successful communication to the central station.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If call waiting is used, enter call waiting disable digits as described above, and also set

 

 

 

 

 

 

 

 

VISTA-10PSIA:

 

 

 

 

 

 

Call Waiting Disable option in field *91.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*41

Primary Phone No.

 

 

Enter the primary phone number. If you enter fewer than 20 digits, exit by pressing [∗]. To clear

 

 

 

 

entries from field, press ∗41∗.

 

 

NOTE: Backup reporting (8 calls are made to the secondary phone number if no kissoff is received

 

 

after 8 attempts to the primary number) is automatic only if there is a secondary number (field ∗42).

 

*42

 

 

Secondary Phone No.

 

 

 

 

Enter the secondary phone number. If you enter fewer than 20 digits, exit by pressing [∗]. To clear

 

 

 

 

 

 

entries from field, press ∗42∗. See backup reporting note for field ∗41. Don’t fill unused spaces.

 

 

 

 

Primary Subs. Acct. No.

 

*43

 

 

 

 

Enter the primary subscriber account number. To clear entries from field, press ∗43∗.

 

 

 

 

Secondary Subs. Acct. No.

 

*44

 

 

 

 

Enter the secondary subscriber account number. To clear entries from field, press ∗44∗.

 

 

 

 

Phone System Select

 

*47

 

 

 

 

Select whether the system will be using pulse or tone dialing, and whether it is on a WATS line.

 

 

 

 

Report Format (Primary/Secondary)

 

*48

 

 

 

 

Select the report format for primary/secondary phone lines from the list on the Programming Guide.

 

 

 

 

Split/Dual Reporting

 

*49

 

 

 

 

Select the desired type of reports to be sent to the primary/secondary numbers. Make selection from the

 

 

 

 

table in the Programming Guide. If “0” selected, all reports go only to the primary number unless

 

 

 

 

unsuccessful, then control will attempt to dial secondary number.

 

 

 

 

Burglary Dialer Delay

 

*50

 

 

 

 

Enter the desired delay time (none, 15, 30, or 45 seconds) before a “BURGLARY ALARM” report is sent

 

 

 

 

to the central station. This delay allows time for the subscriber to avoid sending a false alarm if the

 

 

 

 

alarm was inadvertently caused. This delay does not apply to zone type 24 alarms (silent burglary) or

 

 

 

 

to 24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm), which are always sent

 

 

 

 

as soon as they occur. UL: must be “0”; SIA Guidelines: delay must be minimum of 30 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VISTA-10PSIA:

Delay Time: 1 = 15 secs; 2 = 30 secs; 3 = 45 secs

 

 

 

 

 

 

 

Delay Disable:

0 = use delay set in entry 1

 

 

 

 

 

 

 

1 = dial delay disabled for zones listed in zone list 6 (use zone list 6 to enter those zones that

 

 

 

 

 

 

 

require dial delay to be disabled; these zones ignore the setting in entry 1)

 

 

 

 

 

 

 

UL: Dial delay plus entry delay must not exceed one minute; use zone list 6 to disable dial delay

 

 

 

 

 

 

 

from appropriate zones, if necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SESCOA/Radionics Select

 

*53

 

 

 

 

 

 

Select whether SESCOA format is used.

 

*54

 

 

Dynamic Signaling Delay (Intended for use with Long Range Radio reporting)

Enter the desired time (0-255 seconds in 15-second increments) the panel should wait, per message, for acknowledgment from the first reporting destination (see ∗55) before it attempts to send a message to the second destination. Entering ”0” sends redundant reports to both Primary Dialer and LRR.

UL Installations: For Fire Alarm and UL Burglar Alarm installations without Line Security (Grade A), the maximum Dynamic Signaling Delay must be no more than 15 seconds.

For UL Burglar Alarm installations with Line Security (Grade AA), Dynamic Signaling Delay must be “0”. The reports will be sent to both the dialer and the LRR.

4-3