Installation Instructions
| FIELD |
|
| TITLE and EXPLANATION |
|
|
|
|
|
|
|
|
| Test Restore Report Code |
| *76 |
|
| |
|
|
|
| Enter the appropriate report code, which is sent when the Test mode is exited. |
|
|
|
| UL: Required for UL commercial burglar alarm installations and for residential fire alarm installations. |
Miscellaneous System Fields
| FIELD |
|
| TITLE and EXPLANATION |
|
|
|
|
|
|
|
| |
|
|
|
| Daylight Saving Time Start/End Month |
| |
| *77 |
|
|
| ||
|
|
|
| Enter the start and end month for daylight savings time, if applicable to the region. |
| |
|
|
|
| Daylight Saving Time Start/End Weekend |
| |
| *78 |
|
|
| ||
|
|
|
| Enter the start and end weekend for daylight savings time, if applicable to the region. |
| |
|
|
|
| Output Device Mapping Menu Mode |
| |
| *79 |
|
|
| ||
|
|
|
| Use this menu mode to enter output devices/powerline carrier devices into the system. See Output Device |
| |
|
|
|
| Programming section for procedures. |
| |
|
|
|
| Output Programming Menu Mode |
| |
| *80 |
|
|
| ||
|
|
|
| Use this menu mode to define output functions for use with output devices/powerline carrier devices. See |
| |
|
|
|
| Output Programming section for procedures. |
| |
|
|
|
| Zone List Programming Menu Mode |
| |
| *81 |
|
|
| ||
|
|
|
| Use the menu mode to define zone lists. See Zone List Programming section. |
| |
|
|
|
| Alpha Descriptor Programming Menu Mode |
| |
| *82 |
|
|
| ||
|
|
|
| Use this menu mode to assign alpha descriptors to zones. |
| |
|
|
|
|
|
| |
| *84 |
|
|
| ||
|
|
|
| If enabled, the system will automatically change AWAY mode to STAY mode if the entry/exit door is not |
| |
|
|
|
| opened and closed within the exit delay time after a user arms in AWAY mode from a wired keypad (non- |
| |
|
|
|
| RF device). An Opening report followed by an Armed Stay report is sent to the Central Station. |
| |
|
|
|
| If the door is opened and closed within the exit delay period, the system remains in AWAY mode. |
| |
|
|
|
| Any RF device that arms the system AWAY overrides this feature and the system remains armed AWAY. |
| |
|
|
|
| Cross Zone Timer |
| |
| *85 |
|
|
| ||
|
|
|
| Select the maximum amount of time in which two cross zones must be tripped in an armed system to |
| |
|
|
|
| send an alarm message to the Central Station. If only one cross zone is tripped during this time, a |
| |
|
|
|
| trouble message (CID code 380) for that zone is sent to the Central Station. |
| |
|
|
|
| Assign cross zone pairs in zone list 4. This option not for use in UL installations. |
| |
|
|
|
| Cancel Verify Keypad Display |
| |
| *86 |
|
|
| ||
|
|
|
| Select whether “ ALARM CANCELED” is displayed on the LCD keypad under the following conditions: |
| |
|
|
|
| • After the kissoff of the cancel message to the Central Station, indicating a successful transmission. |
| |
|
|
|
| • When an alarm is successfully canceled before the Central Station received the Alarm message. E.g., if |
| |
|
|
|
| an alarm is incorrectly triggered and the user presses code + OFF before the dial delay time has |
| |
|
|
|
| expired, the message will never go out to the CS. |
| |
|
|
|
| • When the Cancel report is not enabled and the system is disarmed: |
| |
|
|
|
| a. before dialer delay expires (alarm report not sent) message “Alarm Canceled” is displayed. |
| |
|
|
|
| b. after dialer delay expires message “Alarm Canceled” is not displayed. |
| |
|
|
|
| Misc. Fault Delay Time |
| |
| *87 |
|
|
| ||
|
|
|
| Enter the desired fault delay time. Used with zones assigned to a configurable zone type with fault delay |
| |
|
|
|
| on (configurable zone type digit “6”), and sets a zone response time of 15 seconds to 15 min. It can be |
| |
|
|
|
| assigned to zones with sensors that provide a trouble indication when an oil tank is low, or similar |
| |
|
|
|
| applications for critical condition monitoring where a |
| |
|
|
|
| UL: May only be used on |
| |
|
|
|
| burglar alarm installation. |
|
|
|
|
|
| Program Mode Lockout Options |
| |
| *88 |
|
|
| ||
|
|
|
| 0 = standard *98 installer code lockout (reentry only by [∗] + [#] within 50 secs after power up or |
|
downloader)
1 = lockout [∗] + [#] reentry after *98 exit (reentry only by installer code or downloader) 2 = not used
3 = lockout all local programming after *98 exit (reentry by downloader only)