INPUT S/N

L

AXXX-XXXX

 

 

Manually enter the serial number printed on the label for the wireless key or press and release the button to transmit its serial number.

Press [∗] to accept the serial number. The system will check for duplicate.

If necessary, press the [#] key to back up without saving, and re-enter the serial number. Use the [A] key to move forward within the screen, and the [B] key to move backward.

XMIT TO CONFIRM PRESS TO SKIP

If “Yes” was entered at the SET TO CONFIRM? prompt (first prompt following entry into the ∗58 Expert Programming Mode), this display appears.

Confirm serial and loop numbers by activating the wireless key. Refer to the “Confirm” prompt described in *56 Menu mode above for more information on confirming the serial number.

If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and will return you to the ENTER START ZONE NUMBER prompt to enter the starting zone for the next wireless key.

Or you can return to *58 Menu mode by pressing 00 at the Zone Number prompt.

IMPORTANT: When confirmed, the key is not active for arming/disarming until it is assigned to a user number (using the assigning attributes command, attribute “4”). See System Operation section.

[∗] to skip confirm.

Wireless Key Predefined Default Templates

 

 

LOOP 3

YOU MUST

OFF

LOOP 2

PROGRAM

ON

 

THIS BUTTON

 

LOOP 1

LOOP 4

 

ENROLL AS "BR"

5 8 0 4 - 0 0 1 - V 1

Note:

These transmitters are not intended for use in UL installations.

GREEN/YELLOW

 

 

 

LED

 

 

LOOP 2

RED/YELLOW

 

 

LOOP 4

LED

 

 

 

 

(YOU MUST

 

 

 

 

 

 

PROGRAM

 

 

 

THIS BUTTON)

LOOP 3

 

 

 

 

 

 

LOOP 1

• •

•••

••

ENROLL AS "BR"

••

 

 

 

5 8 0 4 B D - 0 0 7 - V 0

5804 Wireless Key Transmitter

 

 

 

5804BD 2-Way Wireless Key Transmitter

 

 

 

 

 

 

 

 

 

 

 

 

For 5804

 

 

 

 

For 5804BD

 

 

TEMPLATE 1

Loop

Function

Zone Type

 

TEMPLATE 4

Loop

 

Function

Zone Type

 

 

1

No Response

23

 

 

1

 

No Response

23

 

 

2

Disarm

22

 

 

2

 

No Response

23

 

 

3

Arm Away

21

 

 

3

 

Arm Away

21

 

 

4

No Response

23

 

 

4

 

Disarm

22

 

TEMPLATE 2

Loop

Function

Zone Type

 

TEMPLATE 5

Loop

 

Function

Zone Type

 

 

1

No Response

23

 

 

1

 

No Response

23

 

 

2

Disarm

22

 

 

2

 

Arm Stay

20

 

 

3

Arm Away

21

 

 

3

 

Arm Away

21

 

 

4

Arm Stay

20

 

 

4

 

Disarm

22

 

TEMPLATE 3

Loop

Function

Zone Type

 

TEMPLATE 6

Loop

 

Function

Zone Type

 

 

1

24-hour audible

7

 

 

1

 

24-hour audible

7

 

 

2

Disarm

22

 

 

2

 

Arm Stay

20

 

 

3

Arm Away

21

 

 

3

 

Arm Away

21

 

 

4

Arm Stay

20

 

 

4

 

Disarm

22

 

5-5

Page 41
Image 41
Honeywell Ademco Security Systems Wireless Key Predefined Default Templates, Input S/N AXXX-XXXX, Wireless Key Transmitter