Event Log Full Report Code

 

FIELD

 

TITLE and EXPLANATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Event Log Full Report Code

 

 

 

*89

 

 

 

 

 

 

Enter the appropriate report code, which is sent when the event log is 80% full (if an event log enable is

 

 

 

 

 

made in field ∗90). If the log becomes full, new messages overwrite the oldest messages in the log.

 

 

 

 

 

Event Log Enables

 

 

 

 

 

 

 

*90

 

 

 

 

 

 

 

 

 

 

Select the types of events (up to 32 events) the system should log. The downloader operator can then

 

 

 

 

 

upload the log and view or print out all or selected categories of the log. The downloader operator can

 

 

 

 

 

also clear the log. The Event log can also be viewed at an alpha keypad. The display/printout at the

 

 

 

 

 

central station will show the date, time, event, and description of occurrences.

 

 

 

 

 

Example: For Alarm/Alarm Restore” and “Open/Close”, enter 9 (1+ 8); to select all events, enter #15.

 

 

 

 

 

Option Selection

 

 

 

 

 

 

 

 

*91

 

 

 

 

 

 

 

 

 

 

 

Select the desired options by adding the values of each desired option. Multiple choice example: for both

 

 

 

 

 

AAV and Exit delay restart, enter # + 12 (4 + 8).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options: Same as VISTA-10P.

 

 

 

 

 

 

 

 

VISTA-10PSIA:

 

 

 

 

 

 

Call Waiting Disable: 0 = call waiting not used

 

 

 

 

 

 

 

1 =

call waiting disable digits (*70) entered in field *40; (when selected, the system dials the entry

 

 

 

 

 

 

 

 

 

in field *40 only on alternate dial attempts; this allows proper dialing in the event call waiting

 

 

 

 

 

 

 

 

 

service is later canceled by the user).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“Exit Delay Restart/reset” option allows use of the [∗] key to restart the exit delay at any time when the

 

 

 

 

 

system is armed STAY or INSTANT. This feature also enables automatic exit delay reset, which resets

 

 

 

 

 

exit delay if the entry/exit door is re-opened and closed before exit delay time expires after arming

 

 

 

 

 

AWAY. Automatic Exit Delay Reset occurs only once during an armed period.

 

 

 

 

 

IMPORTANT: AAV should not be used when Paging or Alarm Reports are sent to a secondary

 

 

 

 

 

number unless the monitoring zone option is used (which pauses calls). Otherwise, the call to the

 

 

 

 

 

secondary number by the communicator after the alarm report will prevent the AAV from taking

 

 

 

 

 

control of the telephone line, and the AAV “Listen in” session cannot take place.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UL UL installations using the AAV feature must use the ADEMCO UVCM module (part of

 

 

 

 

 

 

the ADEMCO UVS system). Exit Delay Restart/Reset must be disabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA Guidelines: Exit delay should be enabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of Reports In Armed Period per Zone (Swinger Suppression)

 

 

 

*93

 

 

 

 

 

 

Select the number (0, 1, or 2) of alarm/alarm restore message pairs per zone allowed to be sent to the

 

 

 

 

 

central station in an armed period. SIA Guidelines: Must be set for option 1 or 2.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Report Pairs: 1 = 1 report pair; 2 = 2 report pairs

 

 

 

 

 

 

 

 

VISTA-10PSIA

 

 

 

 

 

 

Unlimited Reports Enable:

 

 

 

 

 

 

 

 

 

0 =

restrict reports to the setting in entry 1

 

 

 

 

 

 

 

1 =

unlimited reports for zones listed in zone list 7; (use zone list 7 to list zones that require unlimited

 

 

 

 

 

 

 

 

 

reporting; these zones ignore the setting in entry 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Download Phone Number

 

 

 

 

 

 

 

*94

 

 

 

 

 

 

 

 

 

 

Enter the downloading computer phone number.

 

 

 

 

 

Do not fill unused spaces. End field by entering ∗. To clear entries from field, press ∗94∗.

 

 

 

 

 

Ring Count For Downloading

 

 

 

*95

 

 

 

 

 

 

Refer to the chart below and program this field accordingly.

 

 

 

 

 

phone

answer

 

down-

 

 

 

 

 

 

 

 

 

module

machine

 

loading

Set field 95 to…

 

 

 

 

 

yes

 

no

 

no

1-14 (not 0)

 

 

 

 

 

yes

 

yes

 

no

higher than number of rings set on answer machine (e.g., if ans. machine is 4

 

 

 

 

 

 

 

 

 

 

 

 

 

rings, set this field to 5). This allows access to the phone module if the answer

 

 

 

 

 

 

 

 

 

 

 

 

 

machine is turned off.

 

 

 

 

 

yes

 

no

 

yes

1-14 (not 0)

 

 

 

 

 

yes

 

yes

 

yes

15 (bypasses answer machine)

 

 

 

 

 

no

 

no

 

no

0

 

 

 

 

 

 

 

 

no

 

yes

 

no

0

 

 

 

 

 

 

 

 

no

 

no

 

yes

1-14

 

 

 

 

 

 

 

 

no

 

yes

 

yes

15

 

 

 

 

 

NOTE: If “15” is entered to bypass an answering machine, and a 4285 or 4286 Phone Module is included in the system, note the following: When calling in from an off-premises phone, the user should make the initial call, allow 1 or 2 rings only, then hang up, then call again. The phone module will now seize the line, and 2 long tones sound, followed by the usual voice prompt for the access code. If this procedure is not followed, phone module operation will not be possible.

4-7

Page 31
Image 31
Honeywell VISTA-10PSIA Field, TITLE and EXPLANATION, Event Log Full Report Code, Event Log Enables, Option Selection