S E C T I O N 7

Testing the System

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

About Test Procedures

After the installation is complete, you should perform the following tests:

System Test:

Checks that all zones have been installed properly and the system properly

 

responds to faults.

Dialer Test:

Checks that the phone connection to the central station is working properly.

Go/No Go Test:

Checks that transmissions can be received from transmitters. Should be

 

performed before permanently mounting transmitters.

RF Sniffer Mode:

Checks that RF transmitter serial numbers have been properly entered into the

 

system.

Battery Tests:

Automatic battery tests are performed by the system. See Automatic Battery Test

 

paragraph for details.

System Test

With the system in the disarmed state, check that all zones are intact (not faulted). Doors and windows with contacts should be closed, PIRs should be covered (use a cloth to mask them temporarily if necessary). If a “NOT READY” message is displayed, press [∗] to display the faulted zone(s). Restore faulted zone(s) if necessary, so that the “READY” message is displayed.

1. Enter Installer Code + 5 [TEST] , then press “0” at the prompt to start Walk Test mode.

1=DIAL, 0=WALK

(no special display on Fixed-Word Display Keypads)

The following will be displayed:

TEST IN PROGRESS

(“dd” displayed on Fixed-Word Display Keypads)

A Contact ID report will also be sent (code 607)

2.Upon entering the system test mode, the outside sounder should sound for 1 second.

If the backup battery is discharged or missing, the sounder may not turn on and a “LOW BATTERY” report will be transmitted with a “TEST” report.

The keypad will beep about every 40 seconds as a reminder that the system is in the Test mode. NOTE: Wireless motion detectors (Passive Infrared units) will send signals out only if they have been inactive for 3 minutes (conserves battery life).

3.Test all sensors using the procedure described in the User’s Guide “Testing the System” section and/or the each device’s instructions.

4.After checking sensors, turn off the test mode by entering installer code + OFF.

NOTE: Test mode automatically ends after 4 hours. During the final 5 minutes (after 3 hours 55 minutes of Test mode), the keypad emits a double-beep every 30 seconds to alert that the end of Test mode is nearing.

Checking Transmitter Enrollment (Sniffer Mode)

Use this mode to verify that all transmitters have been properly programmed.

1.Press [Installer code] + [#] + 3.

The keypads will display all zone numbers of wireless units programmed into the system. Fault each transmitter in turn, causing each one to send a signal. As the system receives a signal from each transmitter, the zone number of that transmitter disappears from the display.

NOTE: If the communicator is in the process of sending a report to the central station, the system will not go into the Sniffer mode. If so, wait a few minutes, and try again.

2.After all transmitters have been checked, exit the sniffer mode by: [Installer code] + OFF.

IMPORTANT: Sniffer mode does not automatically expire. You must manually exit Sniffer mode (by entering [Installer code] + OFF) to return to normal operation.

7-1

Page 59
Image 59
Honeywell Ademco Security Systems, VISTA-10PSIA setup guide Testing the System, About Test Procedures, System Test