Appendix C

I/O Connectors

C

An 8-pole connector is provided for auxiliary I/O connections to ICA-100 series. The I/O connector provides the physical interface for 2 digital outputs and 2 digital inputs that is used for connecting a diversity of external alarm devices to ICA-100 series such as IR-Sensor and alarm relay. The digital input is used for connecting external alarm devices. Once triggered, images will be taken and e-mailed. The supported transistor output can give a maximum of DC 5V to the externally connected alarm devices. Once triggered, the current will activate the devices.

In 1

In 1 & In 2 is a pair for digital input. It works at voltage 5V

In 2

 

 

 

In 3

In 3 & In 4 is a pair for digital input. It works at voltage 5V

In 4

 

 

 

Out 5 -

Out 5 - & Out 6 + is a pair for digital out. The out put voltage is 5 V and

Out 6 +

maximum current is 100 mA

 

 

 

Out 7 –

Out 7 - & Out 8 + is a pair for digital out. The out put voltage is 5 V and

Out 8 +

maximum current is 100 mA

 

 

 

63