Inactive Timeout

Use the parameter to set an inactive timeout. The unit drops the connection if

 

 

there is no activity on the serial line before the set time expires. To disable the

 

 

inactive timeout enter “0”.

 

 

 

 

 

 

 

 

Example: Use Microsoft Windows Hyper Terminal, TCP/IP Winsock mode

HyperTerminal is a program that you can use to connect to other computers, Telnet sites, online services, and host computers, using either your modem, a null modem cable, a Console cable or Ethernet connection.

The users want to use the TCP Server mode to connect to a Ethernet Switch via Hyper Terminal, Winsock mode

1.Setup Operation Mode and Serial Port of ICS-10x

2.Hyper Terminal set up a new connection with the TCP/IP Winsock

Setup Operation Mode and Serial Port of ICS-10x

1.From the WEB interface, set the Serial operation mode of ICS-10x to “TCP Server” and set the TCP Port Number to “23”.

Figure 4-14Example: TCP Server Configuration screen

2.Set the Serial Port Configuration of ICS-10x as below:

Mode:

RS-232

Baudrare:

9600

 

 

Character Bits:

8

 

 

Parity Type :

none

 

 

Stop Bit :

1

 

 

Hardware Flow Control:

none

 

 